Cygnus 2 Operating Manual

Chapter 13

Troubleshooting, Status and Error Messages

13.1 Status Messages

Some Cygnus 2 status messages will have designators to indicate the Material,
Source or Sensor the status refers.

Table 13-1

indicates designators and to what

they refer. If there is a message that has multiple occurrences, it will display on one
line with multiple designators after it.

There are a few status messages that have a designated area in the status
message area. These messages are noted in

Table 13-1

.

Table 13-1 Status messages

Status Message

Set

Cleared

Screen

Remote
Comm.
Encode

Crystal Fail X…X

One or more of the Sensors
that are called out in currently
active Materials fails to
measure a crystal.
X = Sensor

When all Sensors in use are
good.
When any Sensor in use is
good the Sensor number
clears from the numeric list.

All

Designated area

0x8000,0000
0000,0000

Max Power X…X

Whenever the Source power
reaches the maximum power
programmed for an active
Material. X = Material number

Whenever the Source power is
reduced from the maximum
power for an active Material.

All
Note: This
message will
display in the
cause of stop
area whenever it
is TRUE.
Designated area

0x4000,0000
0000,0000

Test

The general parameter Test
has been set to Yes

The general parameter Test
has been set to No

All.
Designated area

0x2000,0000
0000,0000

A TEST

The general parameter
Advanced Test has been set to
yes.

The general parameter
Advanced Test has been set to
No.

All.
Designated area

0x1000,0000
0000,0000

R Lock

A command was received via
remote communications to lock
the Cygnus 2.
NOTE: R Lock supercedes
L Lock)

A command was received via
remote communications to
unlock the Cygnus 2.

All

Designated area

0x0800,0000
0000,0000

L Lock

A lock code has been
programmed via the keyboard
and the lock has been set.
NOTE: R Lock supercedes
L Lock)

The lock code has been
entered via the keyboard to
unlock the Cygnus 2.

All

Designated area

0x0400,0000
0000,0000