6 query material parameter, 7 update material parameter – INFICON Cygnus 2 Thin Film Deposition Controller User Manual

Page 164

Advertising
background image

9 - 16

IP

N 07

4-

54

5-

P1

E

Cygnus 2 Operating Manual

9.4.6 Query Material Parameter

Command = QM <Command ID> <Material Number>

Command ID = <Byte> See

Table 9-6

Material Number = <Byte> 1- 6

Response = <Integer> | <Float>

Type of response depends on command ID, see Data Type column in

Table 9-6

.

9.4.7 Update Material Parameter

Command = UM <Command ID> <Material Number> <Parameter Value>

Command ID = <Byte> See

Table 9-6

.

Material Number = <Byte> 1- 6

Parameter Value = <Integer> | <Float> Type of value depends on command ID,
see Data Type column in

Table 9-6

.

Response = None (Just header and trailer)

Table 9-6 Material parameters

QM

&

UM

Cmnd

ID

Name

(Units)

Range:

Low Limit/

High Limit/

Default

Data Type

Notes

Update Restrictions

and Display Notes

1

(0x01)

Density

(g/cc)

0.1/

99.999/ 1.0

REAL_5X3

2

(0x02)

Z-Ratio

0.1/ 15.0/

1.0

3

(0x03)

Master Tooling

(%)

1.0/ 999.9/

100.0

REAL_4X1

4

(0x04)

Control Loop

0/ 2/ 0

Encode

0 = NonPID 1 = PI

2 = PID

5

(0x05)

Process Gain

(Å/s/%)

0.01/

999.99/

10.0

REAL_

5F32

6

(0x06)

Time Constant

(seconds)

0.01/

9999.99/

1.0

REAL_

6F32

Gray font if Control Loop =

NonPID

7

(0x07)

Dead Time

(seconds)

0.01/

9999.99/

1.0

REAL_

6F32

Gray font if Control Loop =

NonPID

Advertising