126

Rockwell Automation Publication 20B-UM002G-EN-P - July 2014

Appendix C

Application Notes

The [Pos/Spd Prof Cmd] bits can be set via DPI interface (HIM or Comm) or
digital inputs. When digital input(s) are programmed for “Pos Sel 1-5,” the
starting step of the profile is exclusively controlled by the digital inputs. The DPI
interface value for bits 0-4 will be ignored.

If a digital input is configured for the bit 8-11 functions (see above), the DPI
interface or the digital input can activate the command.

Velocity Regulated Step Types and Parameters

Each of the Velocity Regulated steps has the following associated parameters or
functions. Refer to the following page for descriptions.

Time

When started, the drive will ramp to the desired velocity, hold the speed, and
then ramp to zero in the programmed time for the given step. Dwell time and
batch affect when the next step is executed.

Time Blend

When started, the drive will ramp to the desired velocity and hold speed for the
programmed time. At this point it will transition to the next step and ramp to the
programmed velocity without going to zero speed.

Digital Input

When started, the drive will ramp to the desired velocity and hold speed until the
digital input programmed in the value transitions in the direction defined. When
this occurs, the profile will transition to the next step after dwell and batch
settings are satisfied. It will then ramp to the programmed velocity without going
to zero speed.

Step Type

Value

Velocity

Accel
Time

Decel
Time

Next Step
Condition

Dwell

Batch

Next

Time

Total Move
Time

Speed &
Direction

Accel
Rate

Decel
Rate

Time greater than
[Step Value]

Dwell
Time

Batch
Number

Next
Step

Time Blend

Total Time

Speed &
Direction

Accel
Rate

Decel
Rate

Time greater than
[Step Value]

NA

NA

Next
Step

Digital Input

Digital
Input
Number

Speed &
Direction

Accel
Rate

Decel
Rate

Digital Input logic

Dwell
Time

Batch
Number

Next
Step

Encoder
Incremental
Blend

Position &
Direction

Speed

Accel
Rate

Decel
Rate

At Position [Step
Value]

NA

NA

Next
Step

Parameter
Level

Parameter
Number
+/–

Speed &
Direction

Accel
Rate

Decel
Rate

[Step Value] > or
< [Step Dwell]

Compare
Value

NA

Next
Step

End

NA

NA

NA

Decel
Rate

At Zero transition

Dwell
Time

NA

Stop

NA = Function not applicable to this step type