Applications file – Rockwell Automation 20B PowerFlex 700 AC Drives Vector Control (v4.001 and up) User Manual

Page 67

Advertising
background image

Rockwell Automation Publication 20B-UM002G-EN-P - July 2014

67

Programming and Parameters

Chapter 1

Applications File

Fi

le

Grou

p

No

.

Parameter Name & Description

See

page 16

for symbol descriptions

Values

Re

la

te

d

A

PPLI

CA

TION

S

To

rq

u

e P

ro

vi

n

g

600 [TorqProve Cnfg]

Enables/disables torque/brake proving feature. When “Enabled,” [Digital Out1 Sel] becomes the
brake control. Note: this value is not changed when parameters are reset to factory defaults.

Option Descriptions
Enable

Enables TorqProve features.

Encoderless

Enables encoderless operation – bit 0 must also be enabled.

MicroPosSel

A “1” allows the Micro Position digital input to change the speed command
while the drive is running.

Preload Sel

“0” uses the last torque for preload. “1” uses “TorqRef A” if commanded
direction is forward and “TorqRef B” for reverse.

Load Spd Lim

Enables drive to perform load calculation at base speed. Drive will then limit
operation above base speed depending on load.

NoEnclsBkSlp

A “1” Disables the partial Brake Slip routine from the drive when encoderless
is selected.

StoppedBkSlp

Check for brake slip while stopped.

Test Brake

Before releasing brake, test for slip using [Brake Test Torque].

Fast Stop Bk

Immediately apply brake when a Fast Stop is initiated.

601 [TorqProve Setup]

Allows control of specific torque proving functions through a communication device.

602 [Spd Dev Band]

Defines the allowable difference between the
commanded frequency and encoder feedback
value. A fault will occur when the difference
exceeds this value for a period of time.

Default:

Min/Max:

Units:

2.0 Hz
60.0 RPM

0.1/15.0 Hz
3.0/450.0 RPM
0.1 Hz
0.1 RPM

603

603 [SpdBand Integrat]

Sets the amount of time before a fault is issued
when [Spd Dev Band] is outside its threshold.

Default:

Min/Max:
Units:

60 mSec

1/200 mSec
1 mSec

602

604 [Brk Release Time]

Sets the time between the brake release
command and when the drive begins to
accelerate. In Encoderless mode, this parameter
sets the time to release the brake after drive
starts.

Default:

Min/Max:
Units:

0.10 Secs

0.00/10.00 Secs
0.01 Secs

605 [ZeroSpdFloatTime]

Sets the amount of time the drive is below [Float
Tolerance] before the brake is set. Not used in
Encoderless TorqProve mode.

Default:

Min/Max:
Units:

5.0 Secs

0.1/500.0 Secs
0.1 Secs

0

0

0

0

0

0

0

0

0

0

x

x

x

x

x

x

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 = Enabled

0 = Disabled
x = Reserved

Bit #

Factory Default Bit Values

Enable

Enc

oderless

Micr

oP

osS

el

Pr

eload S

el

Load Spd Lim

NoEnclsBkSlp

Test Br

ak

e

(1)

Fast St

op Bk

(1)

BkSlp SpdLm

t

(1)

St

oppedBkSlp

(1)

(1)

Firmware 6.002 and later.

0

0

0

0

x

x

x

x

x

x

x

x

x

x

x

x

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 = Enabled

0 = Disabled
x = Reserved

Bit #

Factory Default Bit Values

Fast St

op

Micr

o P

os

Dec

el Limit

End St

op