Rockwell Automation 20B PowerFlex 700 AC Drives Vector Control (v4.001 and up) User Manual

Page 69

Advertising
background image

Rockwell Automation Publication 20B-UM002G-EN-P - July 2014

69

Programming and Parameters

Chapter 1

APPLIC

AT

IONS

Oil W

ell

P

ump

634 [TorqAlarm Dwell]

Sets the time that the torque must exceed
[TorqAlarm Level] before [TorqAlarm Action]
takes place. Note: only active with PC pump
applications (see param.

641

).

Default:

Min/Max:
Units:

0.0 Secs

0.0/60.0 Secs
0.1 Secs

635 [TorqAlrm Timeout]

Sets the amount of time a Torque Alarm can be
active until timeout action begins. Note: only
active with PC pump applications (see param.

641

).

Default:

Min/Max:
Units:

0.0 Secs

0.0/600.0 Secs
0.1 Secs

636 [TorqAlrm TO Act]

Sets the drive action when [TorqAlrm Timeout] is
exceeded. Note: only active with PC pump
applications (see p.

641

).

Default:

Options:

0

0
1

“Resume”

“Resume”
“Fault Drive“

637 [PCP Pump Sheave]

Specifies the pump sheave diameter.

Default:

Min/Max:
Units:

20.00 Inch

0.25/200.00 Inch
0.01 Inch

638 [Max Rod Torque]

Sets the desired maximum torque on the
polished rod in a PCP oil well application

Default:

Min/Max:
Units:

500.0 FtLb

0.0/3000.0 FtLb
0.1 FtLb

639 [Min Rod Speed]

Sets the minimum speed for the polished rod in a
PCP oil well application.

Default:

Min/Max:
Units:

0.0 RPM

0.0/199.0 RPM
0.1 RPM

081
646

640 [Max Rod Speed]

Sets the maximum speed for the polished rod in
a PCP oil well application.

Default:

Min/Max:
Units:

300.0 RPM

200.0/600.0 RPM
0.1 RPM

082
646

641 [OilWell Pump Sel]

Selects the type of oil well application.
“Disable” (0) - Disables oil well parameters.
“Pump Jack” (1) - Sets parameters based on
Pump Jack type oil well.
“PC Oil Well” (2) - Sets parameters based on
Progressive Cavity type Pumps.

Default:

Options:

0

0
1
2

“Disable”

“Disable”
“Pump Jack”
“PC Oil Well”

190
279

642 [Gearbox Rating]

Sets the gearbox rating.

Default:

Min/Max:
Units:

640.0 Kin#

16.0/2560.0 Kin#
0.1 Kin#

643 [Gearbox Sheave]

Sets the Sheave diameter on the Gearbox.

Default:

Min/Max:
Units:

0.25 Inch

0.25/100.00 Inch
0.01 Inch

644 [Gearbox Ratio]

Specifies the nameplate gear ratio.

Default:

Min/Max:
Units:

1.00

1.00/40.00
0.01

645 [Motor Sheave]

Sets the sheave diameter on the motor.

Default:

Min/Max:
Units:

10.00 Inch

0.25/25.00 Inch
0.01 Inch

646 [Total Gear Ratio]

Displays the calculated total gear ratio as
follows:

Default:

Min/Max:
Units:

Read Only

0.00/32000.00
0.01

647 [DB Resistor]

Calculates the negative torque maximum
available from the dynamic brake resistor.

Default:

Min/Max:
Units:

10.4 Ohms

0.0/100.0 Ohms
0.1 Ohms

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 16

for symbol descriptions

Values

Rela

ted

[Gearbox Sheave] x [Gearbox Ratio]

[Motor Sheave]

Advertising