Figure 14 - digital input example – Rockwell Automation 20B PowerFlex 700 AC Drives Vector Control (v4.001 and up) User Manual

Page 131

Advertising
background image

Rockwell Automation Publication 20B-UM002G-EN-P - July 2014

131

Application Notes

Appendix C

Example 2: Six Step Velocity Profile (Digital Input-Based)

In each step, the drive ramps at [Step x AccelTime] to [Step x Velocity] in the
direction of the sign of [Step x Velocity] until a digital input is detected. When
the input is detected it transitions to the next step in the profile. This continues
through Digital Input #6 activating step 5. Step 5 is defined as a “Parameter
Level” step. Digital Inputs used in the profile must be defined as “Prof Input.”

Figure 14 - Digital Input Example

IMPORTANT

A transition is required to start each step. If the input is already true when
transitioning to a digital input step, the indexer will not go to the next step.

Step #

[Step x Type]

[Step x
Velocity]

[Step x
AccelTime]

[Step x
DecelTime]

[Step x
Value]

[Step x
Dwell]

[Step x
Batch]

[Step x
Next]

1

Digital Input

300

0.5

0.5

3.00

0.00

1

2

2

Digital Input

50

0.5

0.5

4.00

5.00

1

3

3

Digital Input

-300

0.5

0.5

5.00

0.00

1

4

4

Digital Input

-100

0.5

0.5

6.00

0.00

1

5

5

Param Level

-50

0.5

0.5

701

0.00

1

6

6

End

N/A

N/A

0.5

N/A

0.00

N/A

N/A

0

5

10

15

20

25

30

35

40

45

50

-350

-50

-150

-250

0

50

150

250

350

30

50

70

90

110

130

150

170

Step 1

Digital Input #4

Step 2

Step 3

Time

Step 4

Step 5

Note: Step 5 is a Parameter Level Step.

Step 6

Digital Input #6

5s

Dwell

[Encoder Speed], 415

[Units Traveled], 701

Current Step

Dig In Status, 216

[Profile Status], 700

Digital Input #3

Digital Input #5

10

Encoder Speed

Units Traveled

Profile Status (Scaled)

Current Step

Advertising