Parameter cross reference – by name – Rockwell Automation 20B PowerFlex 700 AC Drives Vector Control (v4.001 and up) User Manual

Page 77

Advertising
background image

Rockwell Automation Publication 20B-UM002G-EN-P - July 2014

77

Programming and Parameters

Chapter 1

Parameter Cross Reference –
by Name

Parameter Name

Number Group

Page

Accel Mask

281

Masks & Owners

56

Accel Owner

293

Masks & Owners

57

Accel Time X

140, 141

Ramp Rates

38

Adj Volt AccTime

675

Adjust Voltage

71

Adj Volt Command

662

Adjust Voltage

70

Adj Volt DecTime

676

Adjust Voltage

71

Adj Volt Phase

650

Adjust Voltage

70

Adj Volt Preset1-7

654-660

Adjust Voltage

70

Adj Volt Ref Hi

652

Adjust Voltage

70

Adj Volt Ref Lo

653

Adjust Voltage

70

Adj Volt S Curve

677

Adjust Voltage

71

Adj Volt Select

651

Adjust Voltage

70

Adj Volt Trim %

672

Adjust Voltage

71

Adj Volt Trim Hi

670

Adjust Voltage

71

Adj Volt Trim Lo

671

Adjust Voltage

71

Adj Volt TrimSel

669

Adjust Voltage

70

Alarm Clear

261

Alarms

53

Alarm Config 1

259

Alarms

53

Alarm X @ Fault

229, 230

Diagnostics

51

Alarm X Code

262-269

Alarms

54

Analog In X Hi

322, 325

Analog Inputs

60

Analog In X Lo

323, 326

Analog Inputs

60

Analog In X Loss

324, 327

Analog Inputs

60

Analog In1 Value

16

Metering

21

Analog In2 Value

17

Metering

21

Analog OutX Hi

343, 346

Analog Outputs

61

Analog OutX Lo

344, 347

Analog Outputs

61

Analog OutX Sel

342, 345

Analog Outputs

61

Anlg In Config

320

Analog Inputs

59

Anlg In Sqr Root

321

Analog Inputs

59

Anlg Out Absolut

341

Analog Outputs

60

Anlg Out Config

340

Analog Outputs

60

Anlg OutX Scale

354, 355

Analog Outputs

61

Anlg OutX Setpt

377, 378

Analog Outputs

61

Auto Rstrt Delay

175

Restart Modes

41

Auto Rstrt Tries

174

Restart Modes

41

Autotune

61

Torq Attributes

25

Autotune Torque

66

Torq Attributes

26

Brake Test Torq

613

Torq Proving

68

Break Frequency

72

Volts per Hertz

27

Break Voltage

71

Volts per Hertz

27

Brk Alarm Travel

610

Torq Proving

68

Brk Release Time

604

Torq Proving

67

Brk Set Time

607

Torq Proving

68

BrkSlip Count

609

Torq Proving

68

Bus Reg Kd

165

Stop/Brake Modes

40

Bus Reg Ki

160

Stop/Brake Modes

39

Bus Reg Kp

164

Stop/Brake Modes

40

Bus Reg Mode X

161, 162

Stop/Brake Modes

40

Commanded Freq

2

Metering

21

Commanded Torque

24

Metering

22

Compensation

56

Torq Attributes

24

Control Status

440

Torq Attributes

27

Control SW Ver

29

Drive Data

22

Counts Per Unit

708

ProfSetup/Status

72

Current Lmt Gain

149

Load Limits

38

Current Lmt Sel

147

Load Limits

38

Current Lmt Val

148

Load Limits

38

Current Rate Limit

154

Load Limits

39

Data In XX

300-307

Datalinks

58

Data Out XX

310-317

Datalinks

58

DB Resistor

647

Oil Well Pump

69

DB Resistor Type

163

Stop/Brake Modes

40

DB While Stopped

145

Stop/Brake Modes

39

DC Brake Level

158

Stop/Brake Modes

39

DC Brake Time

159

Stop/Brake Modes

39

DC Brk Lvl Sel

157

Stop/Brake Modes

39

DC Bus Memory

13

Metering

21

DC Bus Voltage

12

Metering

21

Decel Mask

282

Masks & Owners

56

Decel Owner

294

Masks & Owners

57

Decel Time X

142, 143

Ramp Rates

38

DigIn DataLogic

411

Digital Inputs

64

Dig In Status

216

Diagnostics

49

Digital InX Sel

361-366

Digital Inputs

63

Digital OutX Sel

380, 384,
388

Digital Outputs

65

Dig Out Invert

392

Digital Outputs

66

Dig Out Mask

394

Digital Outputs

66

Dig Out Param

393

Digital Outputs

66

Dig Out Setpt

379

Digital Outputs

64

Dig Out Status

217

Diagnostics

49

Dig OutX Level

381, 385,
389

Digital Outputs

65

Dig OutX OffTime

383, 387,
391

Digital Outputs

65

Dig OutX OnTime

382, 386,
390

Digital Outputs

65

Direction Mask

279

Masks & Owners

56

Direction Mode

190

Direction Config

44

Direction Owner

291

Masks & Owners

57

DPI Baud Rate

270

Comm Control

55

DPI Fdbk Select

299

Comm Control

56

DPI Loss Action

173

HIM Ref Config

44

DPI Port Sel

274

Comm Control

55

DPI Port Value

275

Comm Control

55

DPI Ref Select

298

Comm Control

55

Drive Alarm X

211, 212

Diagnostics

47

Drive Checksum

203

Drive Memory

46

Drive Logic Rslt

271

Comm Control

55

Drive OL Count

219

Diagnostics

49

Drive OL Mode

150

Load Limits

38

Drive Ramp Rslt

273

Comm Control

55

Drive Ref Rslt

272

Comm Control

55

Drive Status 1, 2

209, 210

Diagnostics

47

Drive Status 3

222

Diagnostics

50

Drive Temp

218

Diagnostics

49

Droop RPM @ FLA

152

Load Limits

38

Dyn UserSet Actv

206

Drive Memory

46

Dyn UserSet Cnfg

204

Drive Memory

46

Dyn UserSet Sel

205

Drive Memory

46

Elapsed kWh

14

Metering

21

Elapsed MWh

9

Metering

21

Elapsed Run Time

10

Metering

21

Enc Position Fdbk

414

Speed Feedback

28

Encoder Pos Tol

707

ProfSetup/Status

72

Encoder PPR

413

Speed Feedback

28

Encoder Speed

415

Speed Feedback

28

Encoder Z Chan

423

Speed Feedback

28

Fault 1 Code

243

Faults

52

Fault 1 Time

244

Faults

53

Fault 2 Code

245

Faults

52

Fault 2 Time

246

Faults

53

Fault 3 Code

247

Faults

52

Fault 3 Time

248

Faults

53

Fault 4 Code

249

Faults

52

Fault 4 Time

250

Faults

53

Fault 5 Code

251

Faults

52

Fault 5 Time

252

Faults

53

Fault 6 Code

253

Faults

52

Fault 6 Time

254

Faults

53

Fault 7 Code

255

Faults

52

Fault 7 Time

256

Faults

53

Fault 8 Code

257

Faults

52

Fault 8 Time

258

Faults

53

Fault Amps

225

Diagnostics

50

Fault Bus Volts

226

Diagnostics

50

Fault Clear

240

Faults

52

Fault Clear Mode

241

Faults

52

Fault Clr Mask

283

Masks & Owners

56

Fault Clr Owner

295

Masks & Owners

57

Fault Config 1

238

Faults

52

Fault Speed

224

Diagnostics

50

Fdbk Filter Sel

416

Speed Feedback

28

Feedback Select

80

Spd Mode & Limits

29

Find Home Ramp

714

ProfSetup/Status

73

Find Home Speed

713

ProfSetup/Status

73

Float Tolerance

606

Torq Proving

68

Flux Braking

166

Stop/Brake Modes

40

Flux Current

5

Metering

21

Flux Current Ref

63

Torq Attributes

25

Flux Up Mode

57

Torq Attributes

25

Flux Up Time

58

Torq Attributes

25

Parameter Name

Number Group

Page

Advertising