Rockwell Automation Publication 20B-UM002G-EN-P - July 2014

61

Programming and Parameters

Chapter 1

INPUT

S & OUTPUTS

An

al

og O

u

tpu

ts

342
345

[Analog Out1 Sel]
[Analog Out2 Sel]

Selects the source of the value that drives the
analog output.

Default:

Options:

0 “Output Freq”

See Table

001
002
003
004
005
007
006
012
135
136
137
138
220
219

377
378

343
346

[Analog Out1 Hi]
[Analog Out2 Hi]

Sets the analog output value when the source
value is at maximum.

Default:

Min/Max:

Units:

20.000 mA, 10.000 Volts

0.000/20.000mA
–/+10.000V
0.001 mA
0.001 Volt

340
342

344
347

[Analog Out1 Lo]
[Analog Out2 Lo]

Sets the analog output value when the source
value is at minimum.

Default:

Min/Max:

Units:

0.000 mA, 0.000 Volts

0.000/20.000mA
–/+10.000V
0.001 mA
0.001 Volt

340
342

354
355

[Anlg Out1 Scale]
[Anlg Out2 Scale]

Sets the high value for the range of analog out
scale. Entering 0.0 will disable this scale and max
scale will be used. Example: If [Analog Out Sel] =
“Commanded Trq,” a value of 150 = 150% scale
in place of the default 800%.

Default:

Min/Max:
Units:

0.0

[Analog Out1 Sel]
0.1
Units shown are dependent on
the value in parameter 342/345.

377
378

[Anlg1 Out Setpt]
[Anlg2 Out Setpt]

Controls the analog output value from a
communication device. Example: Set [Data In Ax]
to “377” (value from communication device).
Then set [Analog Outx Sel] to “Param Cntl.”

Default:

Min/Max:

Units:

4.000 mA, 0.000 Volts

0.000/20.000 mA
–/+10.000V
0.001 mA
0.001 Volt

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 16

for symbol descriptions

Values

Rela

ted

(1)

Refer to Option Definitions on

page 62

.

Options

[Analog Out1 Lo] Value

[Analog Out1 Hi] Value

Param. 341 = Signed

Param. 341 = Absolute

0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20-23
24
25

“Output Freq”
“Command Spd”
“Output Amps”
“Torque Amps”
“Flux Amps”
“Output Power”
“Output Volts”
“DC Bus Volts”
“PI Reference”

(1)

“PI Feedback”
“PI Error”
“PI Output”
“%Motor OL”
“%Drive OL”
“CommandedTrq”
“MtrTrqCurRef”

(1)

“Speed Ref”
“Speed Fdbk”
“Pulse In Ref”

(1)

“Torque Est”

(1)

“Scale Block1-4”

(1)

“Param Cntl”

(1)

“SpdFb NoFilt

–[Maximum Speed]
–[Maximum Speed]
0 Amps
–200% Rated
0 Amps
0 kW
0 Volts
0 Volts
–100%
–100%
–100%
–100%
0%
0%
–800% Rated
–200% Rated
–[Maximum Speed]
–[Maximum Speed]
–25200.0 RPM
–800%

0 Hz
0 Hz/RPM
0 Amps
0 Amps
0 Amps
0 kW
0 Volts
0 Volts
0%
0%
0%
0%
0%
0%
0%
0%
0 Hz/RPM
0 Hz/RPM
0 Hz/RPM
0%

+[Maximum Speed]
+[Maximum Speed]
200% Rated
200% Rated
200% Rated
200% Rated
120% Rated Input Volts
200% Rated Input Volts
100%
100%
100%
100%
100%
100%
800% Rated
200% Rated
+[Maximum Speed]
+[Maximum Speed]
+[Maximum Speed]
+800%