Voltage Tolerance

Drive Rating

Nominal Line
Voltage

Nominal Motor
Voltage

Drive Full Power
Range

Drive Operating
Range

200…240

200

200*

200…264

180…264

208

208

208…264

240

230

230…264

380…480

380

380*

380…528

342…528

400

400

400…528

480

460

460…528

500…600
(Frames 0…4 Only)

600

575*

575…660

432…660

500…690

(Frames 5 & 6 Only)

600

575*

575…660

475…759

690

690

690…759

475…759

Drive Full Power Range =

Nominal Motor Voltage to Drive Rated Voltage +10%.
Rated power is available across the entire Drive Full Power Range.

Drive Operating Range =

Lowest (*) Nominal Motor Voltage –10% to Drive Rated Voltage +10%. Drive
Output is linearly derated when Actual Line Voltage is less than the Nominal
Motor Voltage.

EXAMPLE

Calculate the maximum power of a 5 Hp, 460V motor connected to a 480V
rated drive supplied with 342V Actual Line Voltage input.

Actual Line Voltage / Nominal Motor Voltage = 74.3%

74.3%

× 5 Hp = 3.7 Hp

74.3%

× 60 Hz = 44.6 Hz

At 342V Actual Line Voltage, the maximum power the 5 Hp, 460V motor can
produce is 3.7 Hp at 44.6 Hz.

HP @ Motor (Drive Output)

Actual Line Voltage (Drive Input)

Full Power Range

Drive Operating Range

Nominal Motor Voltage -10%

Nominal Motor Voltage

Derated Power Range

Drive Rated Voltage

Drive Rated Voltage +10%

5 HP

3.7 HP

HP @ Motor (Drive Output)

Actual Line Voltage (Drive Input)

342V

460V

480V

528V

Advertising