Rockwell Automation 20B PowerFlex 700 AC Drives Vector Control (v4.001 and up) User Manual

Page 76

Advertising
background image

76

Rockwell Automation Publication 20B-UM002G-EN-P - July 2014

Chapter 1

Programming and Parameters

POS/SPD PROFILE

Pr

ofile

S

tep

1-16

726
736
746
756
766
776
786
796
806
816
826
836
846
856
866
876

[Step 1 Batch]
[Step 2 Batch]
[Step 3 Batch]
[Step 4 Batch]
[Step 5 Batch]
[Step 6 Batch]
[Step 7 Batch]
[Step 8 Batch]
[Step 9 Batch]
[Step 10 Batch]
[Step 11 Batch]
[Step 12 Batch]
[Step 13 Batch]
[Step 14 Batch]
[Step 15 Batch]
[Step 16 Batch]

Sets the number of times to run this step. “0” =
continuously run this step.

Default:

Min/Max:
Units:

1

0/1000000
1

727
737
747
757
767
777
787
797
807
817
827
837
847
857
867
877

[Step 1 Next]
[Step 2 Next]
[Step 3 Next]
[Step 4 Next]
[Step 5 Next]
[Step 6 Next]
[Step 7 Next]
[Step 8 Next]
[Step 9 Next]
[Step 10 Next]
[Step 11 Next]
[Step 12 Next]
[Step 13 Next]
[Step 14 Next]
[Step 15 Next]
[Step 16 Next]

Sets the step number to execute after this step is
complete (including [Step x Batch]).

Default:

Min/Max:
Units:

2

1/16
1