Figure 11 - homing to a limit switch, Figure 12 - homing to limit switch (no feedback) – Rockwell Automation 20B PowerFlex 700 AC Drives Vector Control (v4.001 and up) User Manual

Page 129

Advertising
background image

Rockwell Automation Publication 20B-UM002G-EN-P - July 2014

129

Application Notes

Appendix C

Homing to Limit Switch with Encoder Feedback

When “Find Home” is commanded, the homing routine is run when a
start command is issued. The Homing bit (11) in [Profile Status] will be
set while the homing routine is running. The drive will ramp to the speed
and direction set in [Find Home Speed] at the rate set in [Find Home
Ramp] until the digital input defined as Home Limit is activated. The
drive will then reverse direction at 1/10 the [Find Home Speed] to the
point where the Home Limit switch activated and stop.

Figure 11

shows the sequence of operation for homing to a limit switch

with encoder feedback (without a marker pulse). [Encoder Z Chan] must
be set to “Pulse Input” or “Pulse Check.”

Figure 11 - Homing to a Limit Switch

Homing to Limit Switch w/o Encoder Feedback

When “Find Home” is commanded, the homing routine is run when a
Start command is issued. The Homing bit (11) in [Profile Status] will be
set while the homing routine is running. The drive will ramp to the speed
and direction set in [Find Home Speed] at the rate set in [Find Home
Ramp] until the digital input defined as Home Limit is activated. The
drive will then decelerate to zero. If the switch is no longer activated, the
drive will reverse direction at 1/10 the [Find Home Speed] to the switch
position and then stop. The Home Limit switch will be active when
stopped.

Figure 12

shows the sequence of operation for homing to a limit switch

without encoder feedback.

Figure 12 - Homing to Limit Switch (No Feedback)

20

25

30

35

40

45

50

55

0

5

10

15

20

25

30

Find Home Command

Start Command

Home Limit Input

At Home

Homing

-50

0

50

100

150

200

250

60

15

65

[Encoder Speed], 415

[Units Traveled], 701

[Dig In Status], 216

[Profile Status], 700

Encoder Speed

Profile Status

Units Traveled

Digital In Status

Find Home Command

Start Command

Home Limit Input

At Home

Homing

-50

0

50

100

150

200

20

25

30

45

0

35

[Speed Feedback], 25

[Dig In Status], 216

[Profile Status], 700

Advertising