Figure 15 - encoder incremental w/dwell example – Rockwell Automation 20B PowerFlex 700 AC Drives Vector Control (v4.001 and up) User Manual

Page 132

Advertising
background image

132

Rockwell Automation Publication 20B-UM002G-EN-P - July 2014

Appendix C

Application Notes

Example 3: Five Step Positioner with Incremental Encoder

The first three steps of this indexer are “Encoder Incr” steps followed by an
“Encoder Abs” step to zero and then an “End Hold Position” step. For each
“Encoder Incr” step the drive ramps at [Step x AccelTime] to [Step x Velocity] in
the direction of the sign of [Step xValue]. It then decelerates at the rate of [Step x
DecelTime] to the position programmed in [Step x Value] which sets the desired
units of travel for the step. When the value programmed in [Step x Value] is
reached within the tolerance window programmed in [Encoder Pos Tol], the “At
Position” bit is set in [Profile Status]. In this example a dwell value held each of
the first three steps “At Position” for 1 second. After the [Step x Dwell] time
expires, the profile transitions to the next step. The absolute step is used to send
the profile back to the home position. This is accomplished by programming
[Step 4 Value] to zero.

Figure 15 - Encoder Incremental w/Dwell Example

Step #

[Step x Type]

[Step x
Velocity]

[Step x
AccelTime]

[Step x
DecelTime]

[Step x
Value]

[Step x
Dwell]

[Step x
Batch]

[Step x
Next]

1

Encoder Incr

100

0.5

0.5

10.00

1.00

1

2

2

Encoder Incr

200

0.5

0.5

10.00

1.00

1

3

3

Encoder Incr

300

0.5

0.5

10.00

1.00

1

4

4

Encoder Abs

400

0.5

0.5

0.00

1.00

N/A

5

5

End Hold Position

N/A

N/A

0.5

N/A

0.00

N/A

N/A

90

110

130

150

190

0

5

10

15

20

25

30

Step 1

Step 2

Step 3

Time

Complete

At Position

Step 4

Step 5

-50

-150

-250

-350

-450

50

150

250

350

70

210

[Encoder Speed], 415

[Units Traveled], 701

Current Step

[Profile Status], 700

170

Encoder Speed

Units Traveled

Profile Status

Current Step