Programming and Parameters

Chapter 1

M

O

TO

R C

O

N

TROL

To

rq

A

tt

ri

bu

te

s

437 [Neg Torque Limit]

Defines the torque limit for the negative torque
reference value. The reference will not be
allowed to exceed this value.

Default:

Min/Max:
Units:

–200.0%

–800.0/0.0%
0.1%

053

438 [Torque Setpoint2]

Provides an internal fixed value for Torque
Setpoint when [Torque Ref x Sel] is set to “Torque
Setpt 2.”

Default:

Min/Max:
Units:

0.0%

–/+800.0%
0.1%

440 [Control Status]

Displays a summary status of any condition that can be
limiting either the current or the torque reference.

Read Only

053

441 [Mtr Tor Cur Ref]

Displays the torque current reference value that
is present at the output of the current rate limiter
(parameter 154).

Default:

Min/Max:
Units:

Read Only

–/+32767.0 Amps
0.01 Amps

053

Vo

lt

s p

er

H

er

tz

069 [Start/Acc Boost]

Sets the voltage boost level for starting and
acceleration when “Custom V/Hz” mode is
selected. Refer to parameter 083 [Overspeed
Limit].

Default:

Min/Max:
Units:

Based on Drive Rating

0.0/[Motor NP Volts] x 0.25
0.1 VAC

053
070

070 [Run Boost]

Sets the boost level for steady state or
deceleration when “Fan/Pmp V/Hz” or “Custom
V/Hz” modes are selected. See parameter 083
[Overspeed Limit].

Default:

Min/Max:
Units:

Based on Drive Rating

0.0/[Motor NP Volts] x 0.25
0.1 VAC

053
069

071 [Break Voltage]

Sets the voltage the drive will output at [Break
Frequency]. Refer to parameter 083 [Overspeed
Limit].

Default:

Min/Max:
Units:

[Motor NP Volts] x 0.25

0.0/[Motor NP Volts]
0.1 VAC

053
072

072 [Break Frequency]

Sets the frequency the drive will output at [Break
Voltage]. Refer to parameter 083.

Default:

Min/Max:
Units:

[Motor NP Hz] x 0.25

0.0/[Maximum Freq]
0.1 Hz

053
071

Speed F

ee

dback

412 [Motor Fdbk Type]

Selects the encoder type; single channel or
quadrature. Options 1 & 3 detect a loss of
encoder signal (when using differential inputs)
regardless of the [Feedback Select], param. 080
setting. For FVC Vector mode, use a quadrature
encoder only (option 0/1). If a single channel
encoder is used (option 2/3) in sensorless vector
or V/Hz mode, select “Reverse Dis” (option 2) in
param. 190.

Default:

Options:

0

0
1
2
3

“Quadrature”

“Quadrature”
“Quad Check”
“Single Chan”
“Single Check”

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 16

for symbol descriptions

Values

Rela

ted

FV

FV

FV

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 = Condition True

0 = Condition False
x = Reserved

Bit #

Neg

Trq

CurLim

Pos

TrqC

urLim

NegF

lxC

urLim

PosF

lxC

urLim

Neg

TrqLimit

Pos

TrqLimit

NegP

wr

TrqLim

PosP

wr

TrqLim

Min Slip Lim

Max Slip Lim

Min

TrqC

urLim

VelT

rqRef

Tor

qRef

FldW

eakSts

Obser

ve Sts

VltLimL

eakag

0

0

0

0

0

x

x

x

x

x

x

x

x

x

x

x

26

16

17

18

19

20

21

22

23

24

25

27

28

29

30

31

1 = Condition True

0 = Condition False
x = Reserved

Bit #

VltLimSta

tor

Dr

vV

oltLim

FluxBr

ak

e

Ec

onomiz

e

RevPhaseMot

FV

Advertising