Rockwell Automation Publication 20B-UM002G-EN-P - July 2014

Chapter 1

Programming and Parameters

APPLIC

AT

IONS

To

rq

u

e P

ro

vi

n

g

606 [Float Tolerance]

Sets the frequency level where the float timer
starts. Also sets the frequency level where the
brake will be closed in Encoderless TorqProve
mode.

Default:

Min/Max:

Units:

0.2 Hz
6.0 RPM

0.1/5.0 Hz
3.0/150.0 RPM
0.1 Hz
0.1 RPM

607 [Brk Set Time]

Defines the amount of delay time between
commanding the brake to be set and the start of
brake proving.

Default:

Min/Max:
Units:

0.10 Secs

0.00/10.00 Secs
0.01 Secs

608 [TorqLim SlewRate]

Sets the rate to ramp the torque limits to zero
during brake proving.

Default:

Min/Max:
Units:

10.0 Secs

0.5/300.0 Secs
0.1 Secs

609 [BrkSlip Count]

Sets the number of encoder counts to define a
brake slippage condition. Not used in
encoderless operation.

Default:

Min/Max:
Units:

250

0/65535
1

610 [Brk Alarm Travel]

Sets the number of motor shaft revolutions
allowed during the brake slippage test. Drive
torque is reduced to check for brake slippage.
When slippage occurs, the drive allows this
number of motor shaft revolutions before
regaining control. Not used in Encoderless
TorqProve mode.

Default:

Min/Max:
Units:

1.0 Revs

0.0/1000.0 Revs
0.1 Revs

611 [MicroPos Scale%]

Sets the percent of speed reference to be used
when micropositioning has been selected in
[TorqProve Cnfg]. Bit 2 of [TorqProve Cnfg],
parameter 600 determines if the motor needs to
come to a stop before this setting will take effect.

Default:

Min/Max:
Units:

10.0%

0.1/100.0%
0.1%

361

366
600

612 [Torq Prove Sts]

Displays the status bits for TorqProve.

Read Only

613

[Brake Test Torq]

Sets test torque to use when [Brake Test] is
enabled in [TorqProv Cnfg].

Default:

Min/Max:
Units:

50.0%

0.0/150.0%
0.1%

600

Oil W

ell

P

ump

631 [Rod Load Torque]

Displays the load side torque. [Alarm Config 1],
parameter 259, bit 19 must be enabled to
activate this display.

Default:

Min/Max:
Units:

Read Only

0.00/32000.00 FtLb
0.01 FtLb

632 [TorqAlarm Level]

Sets the level at which the Torque Alarm
becomes active. Note: only active with PC pump
applications (see param.

641

).

Default:

Min/Max:
Units:

0.00 FtLb

0.00/5000.00 FtLb
0.01 FtLb

633 [TorqAlarm Action]

Sets the drive action when the Torque Alarm is
exceeded. Note: only active with PC pump
applications (see param.

641

).

Default:

Options:

0

0
1

“No Action”

“No Action”
“Goto Preset1”

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 16

for symbol descriptions

Values

Rela

ted

0

0

0

0

0

0

0

x

x

x

x

x

x

x

x

x

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 = Enabled

0 = Disabled
x = Reserved

Bit #

EndLimitA

ct

v

Dec

elLimA

ct

v

Micr

oP

osA

ct

v

BrkSlipAlarm

Br

ak

e S

et

LoadT

estA

ct

v

RefL

oadLim

td

v6