104 Configuring the Configurable Flowmeter Module

C.Operations[0].kFactStruct.kFactorForChan[11] Float

REAL

This tag is an ordered pair with tag

C.Operations[0].kFactStruct.FreqAtKFactor

[11]

0.0

C.Operations[0].kFactStruct.kFactorForChan[12] Float

REAL

This tag is an ordered pair with tag

C.Operations[0].kFactStruct.FreqAtKFactor

[12]

0.0

C.Operations[0].kFactStruct.FreqAtKFactor[0]

Float

REAL

100.0

C.Operations[0].kFactStruct.FreqAtKFactor[1]

Float

REAL

Freq[1] for KFactor [1]

0.0

C.Operations[0].kFactStruct.FreqAtKFactor[2]

Float

REAL

Freq[2] for KFactor [2]

500.0

C.Operations[0].kFactStruct.FreqAtKFactor[3]

Float

REAL

Freq[3] for KFactor [3]

0.0

C.Operations[0].kFactStruct.FreqAtKFactor[4]

Float

REAL

Freq[4] for KFactor [4]

0.0

C.Operations[0].kFactStruct.FreqAtKFactor[5]

Float

REAL

Freq[5] for KFactor [5]

0.0

C.Operations[0].kFactStruct.FreqAtKFactor[6]

Float

REAL

Freq[6] for KFactor [6]

0.0

C.Operations[0].kFactStruct.FreqAtKFactor[7]

Float

REAL

Freq[7] for KFactor [7]

0.0

C.Operations[0].kFactStruct.FreqAtKFactor[8]

Float

REAL

Freq[8] for KFactor [8]

0.0

C.Operations[0].kFactStruct.FreqAtKFactor[9]

Float

REAL

Freq[9] for KFactor [9]

0.0

C.Operations[0].kFactStruct.FreqAtKFactor[10]

Float

REAL

Freq[10] for KFactor [10]

0.0

C.Operations[0].kFactStruct.FreqAtKFactor[11]

Float

REAL

Freq[11] for KFactor [11]

0.0

C.Operations[0].kFactStruct.FreqAtKFactor[12]

Float

REAL

Freq[12] for KFactor [12]

0.0

C.OutputSetup[0].FaultMode

Decimal

SINT

Sets the state of output 0 when

communications are lost with the

owner-controller in Fault Mode

0 = Continue operation

1 = Reset Output 0 to OFF when in Fault

Mode

2 = Set Output 0 to ON when in Fault Mode

1

C.OutputSetup[0].ProgMode

Decimal

SINT

Sets the state of output 0 when

communications are lost with the

owner-controller in Program Mode

0 = Continue operation

1 = Reset Output 0 to OFF when in Program

Mode

2 = Set Output 0 to ON when in Program

Mode

0

C.OutputSetup[0].DynamicError

Decimal

SINT

Sets the state of output 0 when a dynamic

error occurs

0 = Continue operation

1 = Reset Output 0 to OFF on Error

2 = Set Output 0 to ON on Error

0

Table 8 - Tag Changes Required for Totalizer Mode Using Prover Function

Name

Style

Data type

Definition

Enter this

Value