Rockwell Automation 1756-CFM ControlLogix Configurable Flowmeter Module User Manual

Page 133

Advertising
background image

133

Rockwell Automation Publication 1756-UM010B-EN-P - December 2011

Software Configuration Tags 133

O.Total[0].RollOverValue

Decimal

DINT

Sets the user-defined rollover value on output

connected to channel 0.

Range of 0 - 2,147,483,647

O.Total[0].CombinedCorrectionFactor

Float

REAL

Unitless factor that is multiplied by Gross Rate with

results shown as NetRate of channel 0.

This value must be set to 1.0 when not used or gross

rate will be 0.

Calculation Type must be set to 0 to use this factor.

O.Total[0].BaseTemperature

Float

REAL

Temperature in °F of output connected to channel 0

O.Total[0].FlowingTemperature

Float

REAL

Temperature in °F of output connected to channel 0

O.Total[0].AtmosphericPressure

Float

REAL

Pressure in psia of output connected to channel 0

O.Total[0].StaticGaugePressure

Float

REAL

Pressure in psig of output connected to channel 0

O.Total[0].BasePressure

Float

REAL

Pressure in psig of output connected to channel 0

O.Total[0].BaseCompressibility

Float

REAL

Default = 1

O.Total[0].FlowingCompressibility

Float

REAL

Default = 1

O.Total[0].FillTotalTarget

Float

REAL

Target for Fill Complete, except when Fill Transition is

greater than this value.

O.Total[0].FillTransition

Float

REAL

When fill cycle is started, trickle flow is initiated when

the Fill Total is equal to or greater than this value. Full

flow is initiated when the Fill Total is less than this

value.

O.Total[0].FillTransitionTimer

Float

REAL

When timed trickle flow is selected, the status remains

ON for this time during this state.

The value must be changed prior to entering the trickle

flow state.

O.Total[1].AlarmEnables

Binary

SINT

O.Total[1].Overrange

Decimal

BOOL

Enables the Overrange alarm on output connected to

channel 1. When the Frequency Period exceeds 100KHz,

this alarm is set.

0 = No Alarm

1 = Alarm Enabled

O.Total[1].Overflow

Decimal

BOOL

Enables the Overflow alarm on output connected to

channel 1. When the Total Counts exceeds the Roll Over

value, this alarm is set.

0 = No Alarm

1 = Alarm Enabled

O.Total[1].Overspeed

Decimal

BOOL

Enables the Overspeed alarm on output connected to

channel 1. When the Speed exceeds the Highest

Allowed Frequency value, this alarm is set.

0 = No Alarm

1 = Alarm Enabled

O.Total[1].Acceleration

Decimal

BOOL

Enables the Acceleration alarm on output connected to

channel 1. When the absolute acceleration exceeds the

Acceleration Alarm value, this alarm is set.

0 = No Alarm

1 = Alarm Enabled

Table 15 - Configurable Flowmeter Module Output Tags

Name

Style

Data type

Definition