134 Software Configuration Tags

O.Total[1].Control

Binary

SINT

O.Total[1].Reset

Decimal

BOOL

O.Total[1].Load

Decimal

BOOL

O.Total[1].ProverEnable

Decimal

BOOL

Enables the prover operation on output connected to

channel 1. Once this bit is enabled, the module waits

for output Z

0

to energize before beginning prover

operations.

0 = Prover operation is disabled

1 = Prover operation is enabled

O.Total[1].FillEnable

Decimal

BOOL

Enables the filling operation on output connected to

channel 1.

0 = Fill operation is disabled

1 = Fill operation is enabled.

O.Total[1].FillStart

Decimal

BOOL

Begins filling operation when Fill Enable is enabled on

output connected to channel 1.

0 = Do not begin filling

1 = Begin filling

O.Total[1].FillHold

Decimal

BOOL

Holds/pauses filling operation on output connected to

channel 1.

0 = Continue filling operation

1 = Hold/pause filling operation

O.Total[1].RollOverValue

Decimal

DINT

Sets the user-defined rollover value on output

connected to channel 1.

Range of 0 - 2,147,483,647

O.Total[1].CombinedCorrectionFactor

Float

REAL

Unitless factor that is multiplied by Gross Rate with

results shown as NetRate of channel 1.

This value must be set to 1.0 when not used or gross

rate will be 0.

Calculation Type must be set to 0 to use this factor.

O.Total[1].BaseTemperature

Float

REAL

Temperature in °F of output connected to channel 1.

O.Total[1].FlowingTemperature

Float

REAL

Temperature in °F of output connected to channel 1.

O.Total[1].AtmosphericPressure

Float

REAL

Pressure in psia of output connected to channel 1.

O.Total[1].StaticGaugePressure

Float

REAL

Pressure in psig of output connected to channel 1.

O.Total[1].BasePressure

Float

REAL

Pressure in psig of output connected to channel 1.

O.Total[1].BaseCompressibility

Float

REAL

Default = 1

O.Total[1].FlowingCompressibility

Float

REAL

Default = 1

O.Total[1].FillTotalTarget

Float

REAL

Target for Fill Complete, except when Fill Transition is

greater than this value.

O.Total[1].FillTransition

Float

REAL

When fill cycle is started, trickle flow is initiated when

the Fill Total is equal to or greater than this value. Full

flow is initiated when the Fill Total is less than this

value.

Table 15 - Configurable Flowmeter Module Output Tags