Glossary

The following terms and abbreviations are used throughout this manual. For
definitions of terms not listed here, refer to the Allen-Bradley Industrial
Automation Glossary, publication

AG-7.1

.

Broadcast Data transmissions to all addresses

Communications format Format that defines the type of information transferred between an I/O

module and its owner controller. This format also defines the tags created for
each I/O module

Compatible match An electronic keying protection mode that requires the physical module and

the module configured in the software to match according to vendor, catalog
number and major revision. In this case, the minor revision of the module
must be greater than or equal to that of the configured slot

Connection The communication mechanism from the controller to another module in the

control system

Coordinated System Time (CST) Timer value which is kept synchronized for all modules within a single

ControlLogix backplane chassis. The CST is a 64 bit number with s
resolution

Direct connection An I/O connection where the controller establishes an individual connection

with I/O modules

Disable keying Option that turns off all electronic keying to the module. Requires no

attributes of the physical module and the module configured in the software to
match

Download The process of transferring the contents of a project on the workstation into

the controller

Electronic keying A system feature which makes sure that the physical module attributes are

consistent with what was configured in the software

Exact match An electronic keying protection mode that requires the physical module and

the module configured in the software to match identically, according to
vendor, catalog number, major revision and minor revision

Field side Interface between user field wiring and I/O module

High Resolution Frequency Mode Operational mode in which CFM module measures incoming pulses over a

user-defined time period up to 2 seconds

Inhibit A ControlLogix process that allows you to configure an I/O module but

prevent it from communicating with the owner controller. In this case, the
controller does not establish a connection

Listen-only connection An I/O connection that allows a controller to monitor I/O module data

without owning the module