10-2

Setting Up Allen-Bradley Ethernet to RIO Block Transfer Pass Thru Communications

Figure 10.1 shows an example:

Figure 10.1
Allen-Bradley Ethernet Communications

Hardware

Required Hardware

The hardware required for this type of communications depends on the drive
type. Refer to the following table:

SCANport-
Compatible
Product

1395
Drive

1336
FORCE
Drive

PLC-5E

RIO

Ethernet

Ethernet

Important: In the Remote I/O
communications module, Switch 1 of SW3
must be On to enable block transfer.

Drive

Required Drive Hardware

Required Computer Hardware

SCANport Product

Remote I/O adapter (1203-GD1,
1203-GK1, or 1336-GM1) and
appropriate cable(s)

Ethernet Interface Running TCP/IP
Protocol

1336 FORCE

PLC Communications Board
(1336T-GT1EN)

Ethernet Interface Running TCP/IP
Protocol

1395

Node Adapter (1395-KP50) or
Multi-Communications Adapter
(1395-KP51)

Ethernet Interface Running TCP/IP
Protocol