Overview

1-5

Using DriveTools32 with an Allen-Bradley SCANport-Compatible Product

You can use DriveTools32 with many Allen-Bradley SCANport-compatible
products. For a list of Allen-Bradley SCANport products, refer to Appendix A,
Products Supported by DriveTools32. If you use DriveTools32 with one of these
products, you have the following options:

Communications

Required Drive Hardware

Required Computer Hardware

Refer To:

RS-232 Point-to-Point Serial

Serial Adapter (1203-SSS, 1203-GD2,
1203-GK2, or 1336-GM2) & appropriate cable(s)

RS-232 port

Chapter 3

DH+ to RIO Block Transfer
Pass Thru (PLC or SLC)

Remote I/O Adapter (1203-GD1, 1203-GK1, or
1336-GM1) & appropriate cable(s)

1784-KT, -KTX, -KTXD, or -PCMK

Chapter 6

RS-232 to ControlNet Direct

ControlNet Adapter (1203-CN1) & appropriate
cables

1770-KFC & RS-232 port

Chapter 7

ControlNet Direct

ControlNet Adapter (1203-CN1) & appropriate
cables

1784-KTC, -KTCX, or -PCC

Chapter 7

RS-232 to ControlNet to RIO
Block Transfer Pass Thru
(PLC)

Remote I/O Adapter (1203-GD1, 1203-GK1, or
1336-GM1) & appropriate cable(s)

1770-KFC & RS-232 port

Chapter 8

ControlNet to RIO Block
Transfer Pass Thru (PLC)

Remote I/O Adapter (1203-GD1, 1203-GK1, or
1336-GM1) & appropriate cable(s)

1784-KTC, -KTCX, or -PCC

Chapter 8

RS-232 to DeviceNet Direct

DeviceNet Adapter (1203-GK5, 1203-GU6,
1336-GM5, or 1336-GM6) & appropriate
cable(s)

1770-KFD & RS-232 port

Chapter 9

DeviceNet Direct

DeviceNet Adapter (1203-GK5, 1203-GU6,
1336-GM5, or 1336-GM6) & appropriate
cable(s)

1784-PCD or -PCIDS

Chapter 9

Ethernet to RIO Block Transfer
Pass Thru

Remote I/O Adapter (1203-GD1, 1203-GK1, or
1336-GM1) & appropriate cable(s)

Ethernet Interface Running TCP/IP

Chapter 10

RSLinx Gateway Server:
Ethernet to DH+ to RIO Block
Transfer Pass Thru

Remote I/O Adapter (1203-GD1, 1203-GK1 or
1336-GM1) & appropriate cable(s)

Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP and
1784-KT, -KTX, -KTXD, or -PCMK

Chapter 11

RSLinx Gateway Server:
Ethernet to ControlNet Direct

ControlNet Adapter (1203-CN1) & appropriate
cables

Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP and
1784-KTC, -KTCX, or -PCC

Chapter 11

RSLinx Gateway Server:
Ethernet to RS-232 Point-to-
Point Serial

Serial Adapter(1203-SSS, 1203-GD2,
1203-GK2, or 1336-GM2) & appropriate cable(s)

Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP and
RS-232 port

Chapter 11

Modem (Serial)

Serial Adapter (1203-SSS, 1203-GD2,
1203-GK2, or 1336-GM2), appropriate cable(s),
null modem converter, and modem

RS-232 port and modem

Chapter 12

ControlLogix

Equipment depends on network to which the
drive is connected.

Equipment depends on network to which the
computer is connected.

Chapter 13

ControlLogix to RIO Block
Transfer Pass Thru

Remote I/O Adapter (1203-GD1, 1203-GK1 or
1336-GM1) & appropriate cable(s)

Equipment depends on network to which the
computer is connected.

Chapter 14

Advertising