Connecting to the drive, Connecting to the drive -7 – Rockwell Automation 9303 DRIVE TOOLS 32 VER 2.50 GETTING STARTED User Manual

Page 113

Advertising
background image

Using RSLinx Gateways

11-7

5.

In the Enter INTERCHANGE Port Mapping # field, type the number of
the KT:0 port used by the gateway driver in the RSLinx Configure Client
Applications
dialog box.

Important: To view the KT Port number used by the gateway driver, select
Configure Client Applications in the RSLinx Communications menu.

6.

If you are using a 1336 FORCE and its drive firmware version is 0.10,
select 1336T Two Word Header (used ONLY for 1336T version 0.10).

Important: If a prompt regarding RIO Pass Thru communications appears, read
the information, and then click OK.

7.

Click OK.

Connecting to the
Drive

After configuring RSLinx and the DriveTools32 application, you are ready to
connect to a drive.

1.

In the Drive menu, select Connect to Drive. A Gateway Network
Connect to Drive
dialog box appears.

2.

Click WHO. A Network WHO dialog box appears.

3.

Double-click the drive or controller (PLC or SLC) to which you want to
connect.