Hardware, Hardware -2, Required hardware – Rockwell Automation 9303 DRIVE TOOLS 32 VER 2.50 GETTING STARTED User Manual

Page 108

Advertising
background image

11-2

Using RSLinx Gateways

Hardware

Required Hardware

The hardware required for this type of communications depends on the drive
type. Refer to the following table:

Drive

Gateway to:

Required Drive Hardware

Required Computer Hardware

SCANport-

Compatible

DH+ to RIO Block Transfer Pass Thru Remote I/O Adapter (1203-GD1,

1203-GK1 or 1336-GM1) and
appropriate cable(s)

Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP
and 1784-KT, -KTX, -KTXD, or -PCMK

ControlNet Direct

ControlNet Adapter (1203-CN1) and
appropriate cables

Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP
and 1784-KTC, -KTCX, or -PCC

RS-232 Serial Point-to-Point

Serial Adapter(1203-SSS, 1203-
GD2, 1203-GK2, or 1336-GM2) and
appropriate cable(s)

Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP
and 1784-KTx, -KL, or -PCMK

1336 FORCE

DH+ Direct

PLC Communications Adapter
Board (1336T-GT1EN)

Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP
and 1784-KT, -KTX, -KTXD, or -PCMK

DH+ to RIO Block Transfer Pass Thru PLC Communications Adapter

Board (1336T-GT1EN)

Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP
and 1784-KT, -KTX, -KTXD, or -PCMK

ControlNet Direct

ControlNet Adapter Board (1336T-
GT3EN), ControlNet Repeater
Adapter (1786-RPA), and ControlNet
Fiber Module (1786-RPFM)

Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP
and 1784-KTC, -KTCX, or -PCC

RS-232 Serial Point-to-Point

Serial Adapter(1203-SSS, 1203-
GD2, 1203-GK2, or 1336-GM2) and
appropriate cable(s)

Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP
and RS-232 port

1395

DH+ Direct

Multi-Communications Adapter
(1395-KP51)

Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP
and 1784-KT, -KTX, -KTXD, or -PCMK

DH+ to RIO Block Transfer Pass Thru Node Adapter (1395-KP50) or

Multi-Communications Adapter
(1395-KP51)

Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP
and 1784-KT, -KTX, -KTXD, or -PCMK

ControlNet Direct

ControlNet Adapter Board (1395-
KP54EN), ControlNet Repeater
Adapter (1786-RPA), and ControlNet
Fiber Module (1786-RPFM)

Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP
and 1784-KTC, -KTCX, or -PCC

A-B Stromberg

DH+ Direct

3500-TBX card
(147096 or 157676)

Client: Ethernet Interface Running TCP/IP
Server: Ethernet Interface Running TCP/IP
and 1784-KT, -KTX, -KTXD, or -PCMK

For a list of SCANport-compatible products, refer to Appendix A, Products Supported by DriveTools32.