Rockwell Automation 9303 DRIVE TOOLS 32 VER 2.50 GETTING STARTED User Manual

Page 54

Advertising
background image

6-4

Setting Up DH+ to RIO Block Transfer Pass Thru Communications

Ensure that the controller connected to the drive is not using any Block
Transfer instructions addressed to the drive in its ladder logic program.

Ensure that the controller connected to the drive is in RUN mode. If it is not
in RUN mode, pass thru messages cannot be delivered to the connected
drive product.

Configuring RSLinx

For DH+ to RIO Block Transfer Pass Thru communications, you must configure
RSLinx for DH+ communications. Refer to the “Configuring RSLinx” section
in Chapter 5, Setting Up DH+ Direct Communications, for instructions on
configuring RSLinx.

Setting Up Communications in a DriveTools32 Application

Before a DriveTools32 application can communicate with a drive, you must
configure the application. To do this, you need to:

1.

Start the DriveTools32 application.

2.

In the Options menu, select Communication Setup. The Communication
Setup
dialog box appears.

3.

Click the DH+ tab.

4.

Under Connect Type, select DH+ To PLC RIO pass-thru.