Troubleshooting

16-3

Invalid operation 3. Verify that you are connected
to the device and the RSLinx and the
DriveTools32 application are properly
configured.

1.

Verify that the drive is powered and cables are securely connected
to it.

2.

Verify that RSLinx is configured correctly.

3.

Restart the DriveTools32 application and verify that you
configured it correctly.

IP Address is no longer valid. Verify that RSLinx
is running, drivers are correctly configured, and
the PLC is still active on the network.

1.

Verify that the needed Ethernet driver is still running in RSLinx.

2.

Verify that the IP address used in RSLinx and the DriveTools32
application is correct.

3.

Verify that the device with this IP address is connected to the
network and powered.

IP address is not a valid address. Verify that you
entered the correct IP address in the
Communication Setup dialog box.

1.

Verify that you entered the correct IP address in the RSLinx
Configure driver for Ethernet dialog box.

2.

Restart the DriveTools32 application.

3.

Verify that you entered the same IP address in the DriveTools32
application Communication Setup dialog box.

4.

Connect to the drive.

Important: If the IP address is used by two different nodes, you will
have to use a new IP address. Contact your network administrator.

IP address is not valid. Verify that you entered
the correct IP address in RSLinx and the
DriveTools32 application and that the PLC has
been correctly set up.

1.

Verify that the correct IP address is entered in the RSLinx
Configure driver for Ethernet dialog box.

2.

Restart the DriveTools32 application.

3.

Verify that the same IP address is entered in the DriveTools32
application Communication Setup dialog box.

4.

Verify that the IP address is correctly set up in the PLC to which
you intend to connect. Refer to the PLC user manual.

Important: If the IP address is used by two different nodes, you will
have to use a new IP address. Contact your network administrator.

IP address that you have entered is used by
another DriveTools32 application. If you want to
use the same address, click OK. Otherwise, click
Cancel.

DriveMonitor32 and another application are attempting to use the
same IP address to communicate with a PLC and a drive
connected to the PLC via RIO communications. This will cause
slower communications. To do so, click OK.

OR

If you do not want slower communications, click Cancel, and then
configure a new driver in RSLinx for the second application.

KT card that is used is not valid. Configure and
map a driver in RSLinx. Refer to the
DriveTools32 Getting Started Manual.

1.

Configure RSLinx for the type of communications that you intend
to use. Refer to the chapter in this manual that provides
instructions for setting up the type of communications that you
intend to use.

2.

Restart the DriveTools32 application.

3.

Configure the DriveTools32 application.

4.

Connect to the drive.

KT port has already been used. Select a new KT
port for this connection.

1.

In the DriveTools32 application Options menu, select
Communication Setup.

2.

In the Enter mapping KT(X) Port # to use field, enter a new,
valid KT(X) port number.

3.

Click OK.

4.

Connect to the drive.

Message

Action