Troubleshooting the Drive

5-19

5.7

Replacement Parts

5.8

Troubleshooting the Drive Using the LCD OIM

The LCD OIM provides immediate visual notification of alarm or fault conditions as
well as the following diagnostic information:

Entries in the fault queue

Fault parameters

Drive status parameters

Selected device version and status information

OIM version information

5.8.1 Accessing the Fault Queue

As described in section 5.4.1, the drive automatically retains a history of the last four
faults that have occurred in the fault queue.

To access the fault queue, press the F4 key at the process display screen, or see
figure 5.4 to access the fault queue from the Main Menu.

Table 5.16 – OIM Cables

Description

Part Number

LCD OIM Cable for remote use

RECBL-LCD

LCD OIM Extender Cable (0.3 meter)

RECBL-F03

LCD OIM Extender Cable (1 meter)

RECBL-F10

LCD OIM Extender Cable (3 meters)

RECBL-F30

LCD OIM Extender Cable (9.0 meters)

RECBL-F90

Figure 5.4 – Accessing the Fault Queue

Diagnostics:

Device Version

OIM Version

View Fault Queue

P0: LiquiFlo 1.5

Stopped Auto

Main Menu

Diagnostics

FltQ# : F#xxxxx
Fault Text String
Accum:
hours:min:sec

1

Cflt

Clrqu

Highlight Diagnostics icon

Highlight item

Monitor