209 drive status 1 – Rockwell Automation Liqui-Flo 1.5 General Purpose and Vector Duty User Manual

Page 78

Advertising
background image

4-46

LiquiFlo 1.5 AC Drive, Software Reference Version 1.2

Present operating condition of the drive.

209

Drive Status 1

Range:

See figure 4.13

Default:

Read Only

Access:

1

Path: Utility>Diagnostics

See also: 210

Figure 4.13 – Drive Status 1 (209)

0

1

1

0

0

0

0

1

0

1

1

1

0

0

0

0

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 = Condition True
0 = Condition False
x = Reserved

Bit #

Ready

Active

Command Dir

Actual Dir

Accelerating

Decelerating

Alarm

Faulted

At Speed

Local ID 0

(1)

Local ID 1

(1)

Local ID 2

(1)

Spd Ref ID 0

(2)

Spd Ref ID 1

(2)

Spd Ref ID 2

(2)

Spd Ref ID 3

(2)

Nibble 1

Nibble 2

Nibble 3

Nibble 4

Bits

(2)

Description

Bits

(1)

Description

15

14

13

12

11

10

9

0
0
0
0
0
0
0
0
1
1
1
1
1
1
1

0
0
0
0
1
1
1
1
0
0
0
0
1
1
1

0
0
1
1
0
0
1
1
0
0
1
1
0
0
1

0
1
0
1
0
1
0
1
0
1
0
1
0
1
0

Ref A Auto
Preset 1 Auto
Preset 2 Auto
Preset 3 Auto
Preset 4 Auto
Preset 5 Auto
Preset 6 Auto
Preset 7 Auto
TB Manual
Port 1 Manual
Port 2 Manual
Port 3 Manual
Port 4 Manual
Port 5 Manual
Port 6 Manual

0
0
0
0
1
1
1
1

0
0
1
1
0
0
1
1

0
1
0
1
0
1
0
1

Port 0 (TB)
Port 1
Port 2
Port 3
Port 4
Port 5
Port 6
No Local Control

Advertising