218 drive temp, 219 drive ol count, 220 motor ol count – Rockwell Automation Liqui-Flo 1.5 General Purpose and Vector Duty User Manual
Page 83

Parameter Descriptions
4-51
Present operating temperature of the drive power section.
Accumulated percentage of drive overload. Continuously operating the drive over
100% of its rating will increase this value to 100% and cause a drive fault.
Accumulated percentage of motor overload. Continuously operating the motor over
100% of the motor overload setting will increase this value to 100% and cause a drive
fault.
Figure 4.19 – Dig Out Status (276)
0
x
x
0
x
x
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1 =Output Energized
0 =Output De-energized
x =Reserved
Bit #
Digital Out1
Digital Out2
Nibble 1
Nibble 2
Nibble 3
Nibble 4
218
Drive Temp
Range:
-/+100 degC [0.1 degC]
Default:
Read Only
Access:
1
Path: Utility>Diagnostics
See also:
219
Drive OL Count
Range:
0.0 to 100.0% [0.1%]
Default:
Read Only
Access:
1
Path: Utility>Diagnostics
See also:
150
220
Motor OL Count
Range:
0.0 to 100.0 [1.0 %]
Default:
Read Only
Access:
1
Path: Utility>Diagnostics
See also:
47, 48