282 decel mask, 283 fault clr mask, 284 mop mask – Rockwell Automation Liqui-Flo 1.5 General Purpose and Vector Duty User Manual

Page 94: 285 local mask

Advertising
background image

4-62

LiquiFlo 1.5 AC Drive, Software Reference Version 1.2

Controls which modules can select Decel Time 1, 2. (142, 143)

Controls which modules can clear a fault.

Controls which modules can issue MOP commands to the drive.

Controls which modules are allowed to take exclusive control of drive logic commands
(except stop). Exclusive local control can be taken only when the drive is stopped.

282

Decel Mask

Range:

See Logic Mask (276)

Default:

See Logic Mask (276)

Access:

1

Path: Communication>Masks & Owners

See also:

288 - 297

283

Fault Clr Mask

Range:

See Logic Mask (276)

Default:

See Logic Mask (276)

Access:

1

Path: Communication>Masks & Owners

See also:

288 - 297

284

MOP Mask

Range:

See Logic Mask (276)

Default:

See Logic Mask (276)

Access:

1

Path: Communication>Masks & Owners

See also:

288 - 297

285

Local Mask

Range:

See Logic Mask (276)

Default:

See Logic Mask (276)

Access:

1

Path: Communication>Masks & Owners

See also:

288 - 297