LiquiFlo 1.5 AC Drive, Software Reference Version 1.2
Scales the upper value of the TB Man Ref Sel selection when the source is an analog
input.
Scales the lower value of the TB Man Ref Sel selection when the source is an analog
input.
Sets the output frequency when a jog command is issued.
Provides an internal fixed speed command value when Speed Ref A = Preset Spd
1-7.
97
TB Man Ref Hi
Range:
-/+Maximum Speed [0.1 Hz]
Default:
Maximum Speed
Access:
0
Path: Speed Command>Speed References
See also: 96
98
TB Man Ref Lo
Range:
-/+Maximum Speed [0.1 Hz]
Default:
0.0 Hz
Access:
0
Path: Speed Command>Speed References
See also:
96
100
Jog Speed
Range:
0 to Maximum Speed [0.1 Hz]
Default:
10.0 Hz
Access:
0
Path: Speed Command>Discrete Speeds
See also:
101
102
103
104
105
106
107
Preset Speed 1
Preset Speed 2
Preset Speed 3
Preset Speed 4
Preset Speed 5
Preset Speed 6
Preset Speed 7
Range:
-/+Maximum Speed [0.1 Hz]
Default:
See table 4.1
Access:
101-107 = 0
Path: Speed Command>Discrete Speeds
See also:
90, 93