165 bus reg kd, 168 start at powerup, 169 flying start en – Rockwell Automation Liqui-Flo 1.5 General Purpose and Vector Duty User Manual

Page 69: 170 flying startgain

Advertising
background image

Parameter Descriptions

4-37

Derivative gain for the bus regulator. Used to control regulator overshoot.

This parameter is not used with LiquiFlo AC drives.

Enables/disables the function which reconnects to a spinning motor at actual RPM
when a start command is issued.

Adjusts the responsiveness of the flying start function. Increasing the value in this
parameter increases the responsiveness of the flying start function.

165

Bus Reg Kd

Range:

0 to 10000

Default:

1000

Access:

1

Path: Dynamic Control>Stop/Brake Modes

See also:

168

Start At PowerUp

Range:

0 = Disabled

Default:

0 = Disabled

Access:

0

Path: Dynamic Control>Stop/Restart Modes

See also:

169

Flying Start En

Range:

0 = Disabled
1 = Enabled

Default:

0 = Disabled

Access:

1

Path: Dynamic Control>Stop/Restart Modes

See also:

170

170

Flying StartGain

Range:

20 to 32767 [1]

Default:

4000

Access:

1

Path: Dynamic Control>Restart Modes

See also:

169