27 rated volts, 28 rated amps, 29 control sw ver – Rockwell Automation Liqui-Flo 1.5 General Purpose and Vector Duty User Manual
Page 38: 30 appl digital output

4-6
LiquiFlo 1.5 AC Drive, Software Reference Version 1.2
The drive input voltage class (208, 240, 400, etc.).
The drive rated output current.
The Main Control board software version.
This parameter is not used with LiquiFlo 1.5 AC drives. The lower byte of this
parameter controls the state of the digital outputs on the AC Line I/O card. The uper
byte controls the operation of the rectifier when configured for manual operation.
27
Rated Volts
Range:
208 to 480 V [0.1 VAC]
Default:
Read Only
Access:
1
Path: Monitor>Drive Data
See also:
28
Rated Amps
Range:
0.0 to 6553.5 Amps [0.1 Amps]
Default:
Read Only
Access:
1
Path: Monitor>Drive Data
See also:
29
Control SW Ver
Range:
0.000 to 65.256 [0.001]
Default:
Read Only
Access:
1
Path: Monitor>Drive Data
See also:
196
30
Appl Digital Output
Range:
See figure 4.1
Default:
See figure 4.1
Access:
1
Path: Monitor>Application
See also:
Figure 4.1 – Appl Digital Output (30)
1
0
0
1
1
1
x
x
0
0
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1 =Enabled
0 =Disabled
x =Reserved
Bit #
Factory Default Bit Values
Digital Output 1
Digital Output 2
Digital Output 3
Digital Output 4
Digital Output 5
Digital Output 6
Close Pre-charge
Enab
le Rectifier
Nibble 1
Nibble 2
Nibble 3
Nibble 4