288 stop owner, 289 start owner, 290 jog owner – Rockwell Automation Liqui-Flo 1.5 General Purpose and Vector Duty User Manual

Page 95: 291 direction owner

Advertising
background image

Parameter Descriptions

4-63

Modules that are presently issuing a valid stop command.

Modules that are presently issuing a valid start command.

Modules that are presently issuing a valid jog command.

Adapter that currently has exclusive control of direction changes.

288

Stop Owner

Range:

See figure 4.28

Default:

Read Only

Access:

1

Path: Communication>Masks & Owners

See also: 276 - 285

Figure 4.28 – Stop Owner

0

0

0

1

0

0

x

x

x

x

x

x

x

x

x

x

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Issuing Command
0 =No Command
x =Reserved

Bit #

Digital In

DPI P

or

t 1

DPI P

or

t 2

DPI P

or

t 3

DPI P

or

t 4

DPI P

or

t 5

Reser

ve

d

Nibble 1

Nibble 2

Nibble 3

Nibble 4

289

Start Owner

Range:

See Stop Owner (288)

Default:

Read Only

Access:

1

Path: Communication>Masks & Owners

See also:

276 - 285

290

Jog Owner

Range:

See Stop Owner (288)

Default:

Read Only

Access:

1

Path: Communication>Masks & Owners

See also:

276 - 285

291

Direction Owner

Range:

See Stop Owner (288)

Default:

Read Only

Access:

1

Path: Communication>Masks & Owners

See also:

276 - 285