10 to 15, 2 thr – Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual

Page 32

Advertising
background image

5-

2

Aut

o

Max

Net

w

or

k Comm

unicat

ion
O

p

tion
B

oard

Table 5.2 – FlexPak 3000 Original Register Map, Drop_1: Master Read Registers, BASIC and FULL Connections. Runtime Signal Data (Drive Output Data)

Register

Bit

Parameter Name (Number)

Description

Settings

0

Drive status word 1

Bit-packed word containing information on the present status of the drive

0

Drive ready

1

Drive running

2

Fault active

3

Drive jogging

4

Forward/reverse command

0=forward; 1=reverse

5

Drive stopping

6

Tune/config input enable loopback

0=disabled; 1=enabled

7

Tune/config update synch. flag loopback (master read)

8

Alarm active

9

In current limit

10

Coast/DB interlock

0=open; 1=closed

11

Customer interlock

0=open; 1=closed

12

Parameter processing error

0=no errors; 1=one or more errors

13

Terminal strip forward/reverse input state (terminal 5)

14

Terminal strip auto/manual input state (terminal 6)

15

Terminal strip fault/alarm reset input state (terminal 10)

1

SPD

SOURCE

SELECT

OUT

(P.193)

Selected speed/voltage loop reference value

4095 at

TOP

SPEED

(P.011)

2

SPD

LOOP

REFERENCE

(P.295)

Final speed/voltage loop reference value

4095 at

TOP

SPEED

(P.011)

3

SPD

LOOP

FEEDBACK

(P.296)

Final speed/voltage loop feedback value after all scaling

4095 at

TOP

SPEED

(P.011)

4

SPD

LOOP

OUTPUT

(P.299)

Speed loop

PI

block output value

4095 at

MAXIMUM

CURRENT

(P.007

5

ARMATURE

VOLTAGE

(P.289)

Armature voltage feedback value

4095 at

MOTOR

RATED

ARM

VOLTS

(P.009)

6

Average

CML

feedback

CML

feedback average over eight

CML

scans

4095 at

MAXIMUM

CURRENT

(P.007)

7

Network Output Register 1

Value of the parameter selected by

NETW

OUT

REG

1

SELECT

(P.902)

If no valid parameter value selected,
0=motor speed in

RPM

8

Network Output Register 2

Value of the parameter selected by

NETW

OUT

REG

2

SELECT

(P.903)

If no valid parameter value selected,
0=armature voltage in volts

9

Network Output Register 3

Value of the parameter selected by

NETW

OUT

REG

3

SELECT

(P.904)

If no valid parameter value selected,
0=armature current in amps*10 or amps

10 to 15

Tunable, Configurable and Status Data

See table 5.3 on page 5-4.

Runtime signal data are updated by the regulator every 5 msec, unless

FEEDBACK

SELECT

(P.200) is set to

ARMATURE

VOLT

, in which case the update time is 10 msec.