Table 5.6 – FlexPak 3000 Original Register Map, Drop_1: Master Write Registers, BASIC and FULL Connections. Configurable Data (Drive Input Data)

Register Parameter Name (Number)

Description

Settings

61

FEEDBACK

SELECT

(P.200)

Type of feedback for speed/voltage loop feedback

0=

ARMATURE

VOLT

; 1=

DC

TACH

; 2 =

PULSE

TACH

; 3=

AC

TACH

62

NETW

CONNECT

TYPE

(P.910)

AutoMax network connection type

0=

BASIC

; 1=

FULL

63

AMX

NETW

REF

SELECT

(P.911)

AutoMax network reference selection

0=

DIRECT

; n=

BROADCAST

n (n=1 to 8)

Configurable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit=1 and the drive is not running or jogging

Table 5.7 – FlexPak 3000 Original Register Map, Drop_2: Master Read Registers, FULL Connection. Runtime Signal Data (Drive Output Data)

Register

Parameter Name (Number)

Description

Settings

0

ANALOG

AUTO

REFERENCE

(P.188)

The analog reference value in auto mode after all scaling 4095 at

TOP

SPEED

(P.011)

1

Reserved

2

ANALOG

MAN

TRIM

REF

(P.194)

Analog manual trim reference input value

4095 at

TOP

SPEED

(P.011)

3 to 10

Reserved

Runtime signal data are updated by the regulator every 5 msec, unless

FEEDBACK

SELECT

(P.200) is set to

ARMATURE

VOLT

, in which case the update time is 10 msec.

Table 5.8 – FlexPak 3000 Original Register Map, Drop_2: Master Read Registers, FULL Connection. Tunable, Configurable, and Status Data (Drive Output Data)

Register

Bit

Parameter Name (Number)

Description

Settings

11

OCL

RAMP

OUTPUT

(P.846)

OCL

reference S-curve block output

4095

12

OCL

OUTPUT

(P.848)

Outer control loop output value

RPM

13

TOP

SPEED

(P.011)

Highest running speed of motor

RPM

14

JOG

SPEED

1 (P.012)

Operating speed while jogging

RPM

15

JOG

ACCEL

/

DECEL

TIME

(P.013)

Minimum time in which jog reference can change from
zero to

TOP

SPEED

(P.011) and from

TOP

SPEED

to zero

seconds * 10

16

S

-

CURVE

ROUNDING

(P.014)

Amount of smoothing of speed/voltage loop reference

%

17

REVERSE

DISABLE

(P.015)

Prevents speed/voltage loop ref. from going negative

0=

OFF

(bipolar ref); 1=

ON

(positive ref)

18

ANLG

AUTO

SIGNAL

TYPE

(P.100)

Type of signal applied to analog auto reference input

0=0-10V; 1=±10V; 2=4-20mA; 3=10-50mA

19

ANLG

AUTO

GAIN

ADJ

(P.101)

Scales analog auto reference signal

gain * 1000

20

ANLG

AUTO

ZERO

ADJ

(P.102)

Offset removed from analog auto reference signal

21

AUTO

REFERENCE

SELECT

(P.103)

Selects the type of auto reference

0=

ANALOG

; 1=

FREQUENCY

IN

22

ANLG

MAN

REF

GAIN

ADJ

(P.104)

Scales the analog manual reference gain

gain * 1000

Tunable, configurable, and status data are updated by the regulator approximately every 600 msec.