ANALOG

TACH

GAIN

ADJ

(P.201)

Scales analog tachometer feedback signal

gain * 1000

41

ANALOG

TACH

ZERO

ADJ

(P.202)

Offset removed from analog tachometer feedback signal

42

ARM

VOLTAGE

GAIN

ADJ

(P.204)

Scales the armature voltage signal

gain * 1000

43

ARM

VOLTAGE

ZERO

ADJ

(P.205)

Offset removed from armature voltage feedback

44

SPD

LEADLAG

RATIO

(P.213)

Ratio between low and high break frequencies of speed
feedback lead/lag block

45

SPD

LEADLAG

LOW

FREQ

(P.214)

Low break frequency of speed feedback lead/lag block

radians/second * 100

46

SPD

LOOP

LAG

FREQ

(P.215)

Lag break frequency for the speed loop forward path lag
block

radians/second * 100

47

SPD

LEADLAG

SELECT

(P.216)

Speed/voltage loop lead/lag block select

0=

LEAD

/

LAG

; 1=

BYPASS

; 2=

LAG

/

LEAD

48

SPD

LOOP

LAG

BYPASS

(P.217)

Speed/voltage loop lag block bypass

0=

OFF

(not bypassed); 1=

ON

(bypassed)

49

CML

FEEDBACK

GAIN

ADJ

(P.300)

Current minor loop feedback gain adjust

gain * 1000

52

NETW

COMM

LOSS

SELECT

(P.901)

Selects how the drive responds to network
communication loss

0=

FAULT

; 1=

USE

LAST

REF

; 2=

USE

TRMBLK

REF

Table 6.15 – FlexPak 3000 Alternate Register Map, Drop_3: Master Write Registers, FULL Connection. Configurable Data (Drive Input Data)

Register

Bit

Parameter Name (Number)

Description

Settings

50

TACH

LOSS

SCR

ANGLE

(P.608)

SCR firing angle used in tach loss detection logic

degrees

51

FIELD

REF

SELECT

(P.521)

Selects reference source for the field current regulator

0 =

REGISTER

; 1=

ANALOG

MAN

TRIM

REF

;

2=

ANALOG

IN

1; 3=

ANALOG

IN

2

53

0

NEG

CUR

LIM

INV

EN

(P.226)

Enables negative current limit inverter

0 =

DISABLED

; 1 =

ENABLED

1

OCL

PROP

TRIM

SELECT

(P.813)

Sets

OCL

output proportional to absolute value of speed

reference at the output of the speed loop S-curve block

0 =

DISABLED

; 1 =

ENABLED

2

OCL

TYPE

3

POSN

REG

EN

(P.814

Implements type 3 position regulator

3

STOP

DECEL

SELECT

(P.122)

Selects the deceleration time for ramp stop sequences

1=

DECELERATION

TIME

; 2=

RAMP

STOP

DECEL

TIME

4

Reserved

5

CML

REF

LIMIT

SELECT

(P.311)

Source for

CML

positive and negative current limits

1=

SPD

LOOP

PI

LIMITS

; 2=

REGISTER

6 to 15 Reserved

Configurable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit=1 and the drive is not running or jogging.

Table 6.14 – FlexPak 3000 Alternate Register Map, Drop_3: Master Write Registers, FULL Connection. Tunable Data (Drive Input Data) (Continued)

Register

Bit

Parameter Name (Number)

Description

Settings

Tunable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit = 1.