Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual

Page 77

Advertising
background image

W
ebPak

3000 Drives

: Regist

er
M

a

p

7-

9

9

Current memory

10

Memory save

11

Current/speed

12

Diameter sel A

13

Diameter sel B

14

Tune/config input enable: Determines what is read from
network. “Read all” includes control/reference, tunable,
and configurable inputs

0=

READ

ONLY

CONTROL

/

REFERENCE

INPUTS

1=

READ

ALL

15

Network sync

33

Network Reference

Speed/voltage loop or

CML

reference value when

CONTROL

SOURCE

SELECT

(P.000) is set to

NETWORK

and

AMX

NETW

REF

SELECT

(P.911)=0

34

NETW

IN

REG

1

Written by network master. Read this value through the

OIM

using

NETW

IN

REG

1 (P.905)

35

NETW

IN

REG

2

Written by network master. Read this value through the

OIM

using

NETW

IN

REG

2 (P.906)

36

NETW

IN

REG

3

Written by network master. Read this value through the

OIM

using n

ETW

IN

REG

3 (P.907)

37

TAPER

REGISTER

(P.860)

Determines amount of taper to apply to the tension
reference when

TAPER

TYPE

(P.863) =

REGISTER

0.000 to 1.000

38

FIELD

REF

REGISTER

(P.513)

Reference for the field current loop

4095 at

MOTOR

HOT

FLD

AMPS

(P.510)

39

POSITION

REFERENCE

(P.240)

Dancer position reference.

-4095 to 4095

COUNTS

Table 7.5 – WebPak 3000 Register Map, Drop_1: Master Write Registers, BASIC and FULL Connections. Control/Reference Data (Drive Input Data) (Continued)

Register

Bit

Parameter Name (Number)

Description

Settings

Control/reference data are read by the regulator every 10 msec.