Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual

Page 78

Advertising
background image

7-

10

Aut

o

Max

Net

w

or

k Comm

unicat

ion
O

p

tion
B

oard

Table 7.6 – WebPak 3000 Register Map, Drop_1: Master Write Registers, BASIC and FULL Connections. Tunable Data (Drive Input Data)

Register

Bit

Parameter Name (Number)

Description

Settings

40

DIAMETER

REGISTER

(P.874)

Value assigned to

NORM

ROLL

DIAMETER

(P.131) when

DIAMETER

CALC

ENABLE

(P.826) =

DISABLE

.

1.000 to 2.000

41

ACCELERATION

TIME

(P.001)

Min. time to accelerate from zero to

GEAR

IN

SPEED

(P.011)

seconds * 10

42

DECELERATION

TIME

(P.002)

Min. time to decelerate from

GEAR

IN

SPEED

(P.011) to

zero

seconds * 10

43

MINIMUM

SPEED

(P.003)

Lowest operating speed

RPM

44

MAXIMUM

SPEED

(P.004)

Highest operating speed

RPM

45

POSITIVE

CURRENT

LIM

(P.005)

Highest amount of current for the forward bridge

46

NEGATIVE

CURRENT

LIM

(P.006)

Highest amount of current for reverse bridge

47

S

-

CURVE

ROUNDING

(P.014)

Amount of smoothing of speed/voltage loop reference

0 to 50%

48

TRIM

RANGE

(P.109)

Amount the trim reference will affect the drive reference

0.0 to 100.0%

49

SPD

LOOP

PI

PROP

GAIN

(P.211)

Speed loop

PI

proportional gain

0.10 to 128.00

50

SPD

LOOP

PI

LEAD

FREQ

(P.212)

Speed loop

PI

block lead break frequency

51

CML

PI

PROP

GAIN

(P.301)

CML

PI

proportional gain

52

CML

PI

LEAD

FREQUENCY

(P.302)

CML

PI

lead break frequency

0.000 to 4.000

53

TEN

PI

PROP

GAIN

(P.841)

Tension loop

PI

block proportional gain

0.001 to 32.767

54

TEN

PI

LEAD

FREQ

(P.840)

Tension loop

PI

block lead frequency

0.00 to 141.37 radians/second

55

TENSION

PI

LIMIT

(P.853)

Tension loop pi block high and low limits

0 to 4095

COUNTS

56

JOG

SPEED

(P.012)

Operating speed while jogging

0 to

BASE

SPEED

(P.017) in

FPM

57

STOP

MODE

SELECT

(P.114)

Selects how drive responds to a normal stop command

RAMP

;

COAST

/

DB

;

CURRENT

LIMIT

58

NETW

OUT

REG

1

SELECT

(P.902) Number of the parameter readable in Drop_1, register 7

If no valid parameter value selected, this is set to
0=motor speed in

RPM

59

NETW

OUT

REG

2

SELECT

(P.903) Number of the parameter readable in Drop_1, register 8

If no valid parameter value selected, this is set to
0=armature voltage in volts

60

NETW

OUT

REG

3

SELECT

(P.904) Number of the parameter readable in Drop_1, register 9

If no valid parameter value selected, this is set to
0=armature current in amps*10 or amps

Tunable data are read by the regulator approximately every 600 msec while Tune/Config Input Enable bit=1.