Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual
Page 33

F
lex
Pak
3000 Drives
: O
rig
inal Regist
er
M
a
p
5-
3
16
ANALOG
AUTO
REFERENCE
(P.188)
The analog reference value in auto mode after all scaling 4095 at
TOP
SPEED
(P.011)
17
ANALOG
MAN
TRIM
REF
(P.194)
Analog manual trim reference input value
4095 at
TOP
SPEED
(P.011)
18
ANLG
IN
1 (P.492)
I/O Exp. kit analog input 1 after gain and zero applied
4095 at full scale
19
ANLG
IN
2 (P.493)
I/O Exp. kit analog input 2 after gain and zero applied
4095 at full scale
20
FREQ
IN
(P.491)
I/O Expansion kit frequency input value after all scaling
4095 at full scale
21
OCL
OUTPUT
(P.848)
Outer control loop output value
RPM
22
FIELD
FEEDBACK
(P.589)
Motor field current feedback value after scaling and gain 4095 at
MOTOR
HOT
FLD
AMPS
(P.510)
23
AC
LINE
VOLTAGE
(P.392)
Measured AC line
RMS
voltage
volts
RMS
Table 5.2 – FlexPak 3000 Original Register Map, Drop_1: Master Read Registers, BASIC and FULL Connections. Runtime Signal Data (Drive Output Data) (Continued)
Register
Bit
Parameter Name (Number)
Description
Settings
Runtime signal data are updated by the regulator every 5 msec, unless
FEEDBACK
SELECT
(P.200) is set to
ARMATURE
VOLT
, in which case the update time is 10 msec.