Table 5.5 – FlexPak 3000 Original Register Map, Drop_1: Master Write Registers, BASIC and FULL Connections. Tunable Data (Drive Input Data)

Register

Bit

Parameter Name (Number)

Description

Settings

40

ACCELERATION

TIME

(P.001)

Min. time to accelerate from zero to

TOP

SPEED

(P.011)

seconds * 10

41

DECELERATION

TIME

(P.002)

Min. time to decelerate from

TOP

SPEED

(P.011) to zero

seconds * 10

42

MINIMUM

SPEED

(P.003)

Lowest operating speed

RPM

43

MAXIMUM

SPEED

(P.004)

Highest operating speed

RPM

44

POSITIVE

CURRENT

LIM

(P.005)

Highest amount of current for the forward bridge

% of

MOTOR

RATED

ARM

AMPS

(P.008)

45

NEGATIVE

CURRENT

LIM

(P.006)

Highest amount of current for reverse bridge

% of

MOTOR

RATED

ARM

AMPS

(P.008)

46

S

-

CURVE

ROUNDING

(P.014)

Amount of smoothing of speed/voltage loop reference

%

47

TRIM

RANGE

(P.109)

Amount the trim reference will affect the drive reference

%

48

SPD

LOOP

PI

PROP

GAIN

(P.211)

Speed loop

PI

proportional gain

gain * 100

49

SPD

LOOP

PI

LEAD

FREQ

(P.212)

Speed loop

PI

block lead break frequency

radians/second * 100

50

CML

PI

PROP

GAIN

(P.301)

CML

PI

proportional gain

gain * 1000

51

CML

PI

LEAD

FREQUENCY

(P.302)

CML

PI

lead break frequency

radians/second

52

CML

REF

RATE

LIMIT

(P.303)

Min. time for

CML

ref. to go from zero to

MAXIMUM

CURRENT

milliseconds

53

JOG

SPEED

1 (P.012)

Operating speed while jogging

RPM

54

STOP

MODE

SELECT

(P.114)

Selects how drive responds to a normal stop command

0=

RAMP

; 1=

COAST

/

DB

; 2=

CURRENT

LIMIT

55

IR

COMPENSATION

(P.206)

Armature voltage loss compensation

%

56

CURRENT

COMPOUNDING

(P.209)

Sets the level of current compounding

%

57

NETW

COMM

LOSS

SELECT

(P.901)

How the drive responds to network communication loss

0=

FAULT

; 1=

USE

LAST

REF

; 2=

USE

TRMBLK

REF

,

3=

USE

TRMBLK

CNTL

58

NETW

OUT

REG

1

SELECT

(P.902) Number of the parameter readable in Drop_1, register 7

If no valid parameter value selected, this is set to
0=motor speed in

RPM

59

NETW

OUT

REG

2

SELECT

(P.903) Number of the parameter readable in Drop_1, register 8

If no valid parameter value selected, this is set to
0=armature voltage in volts

60

NETW

OUT

REG

3

SELECT

(P.904) Number of the parameter readable in Drop_1, register 9

If no valid parameter value selected, this is set to
0=armature current in amps*10 or amps

Tunable data are read by the regulator approximately every 600 msec while Tune/Config Input Enable bit=1