F

lex
Pak

3000 Drives

: O
rig

inal Regist

er
M

a

p

5-

11

60

OCL

FEEDBACK

SELECT

(P.804)

Source of

OCL

feedback

0=

NONE

; 1=

CML

FEEDBACK

; 2=

ANALOG

IN

1; 3=

ANALOG

IN

2; 4=

SPEED

LOOP

OUTPUT

; 5=

ANALOG

AUTO

REFERENCE

;

5=

ANALOG

AUTO

REFERENCE

; 6=

NETW

IN

REG

1; 7=

NETW

IN

REG

2; 8=

NETW

IN

REG

3

61

TOP

SPEED

(P.011)

Highest running speed of motor

RPM

62

REVERSE

DISABLE

(P.015)

Prevents speed/voltage loop ref. from going negative

0=

OFF

(bipolar ref); 1=

ON

(positive ref)

63

ANLG

AUTO

SIGNAL

TYPE

(P.100)

Type of signal applied to analog auto reference input

0=0-10V; 1=±10V; 2=4-20mA; 3=10-50mA

Table 5.11 – FlexPak 3000 Original Register Map, Drop_3: Master Read Registers, FULL Connection. Runtime Signal Data (Drive Output Data)

Register

Bit

Parameter Name (Number)

Description

Settings

0

ANALOG

TACH

FEEDBACK

(P.291)

Analog tachometer feedback signal after all scaling

4095 at

TOP

SPEED

(P.011)

1

PULSE

TACH

FEEDBACK

(P.292)

Pulse encoder feedback signal after all scaling

4095 at

TOP

SPEED

(P.011)

2

SPD

LOOP

ERROR

(P.297)

Speed loop error

3

CML

REFERENCE

(P.396)

Amplitude and rate limited value of selected

CML

ref.

4095 at

MAXIMUM

CURRENT

(P.007)

4

FIELD

REFERENCE

(P.590)

Field current reference

4095 at

MOTOR

HOT

FLD

AMPS

(P.510)

5

FIELD

FEEDBACK

(P.589)

Motor field current feedback value after scaling and gain 4095 at

MOTOR

HOT

FLD

AMPS

(P.510)

6 to 11

Reserved

Runtime signal data are updated by the regulator every 5 msec, unless

FEEDBACK

SELECT

(P.200) is set to

ARMATURE

VOLT

, in which case the update time is 10 msec.

Table 5.12 – FlexPak 3000 Original Register Map, Drop_3: Master Read Registers, FULL Connection. Tunable, Configurable, and Status Data (Drive Output Data)

Register

Bit

Parameter Name (Number)

Description

Settings

12

MAXIMUM

CURRENT

(P.007)

Highest amount of current, either positive or negative

% of

MOTOR

RATED

ARM

AMPS

(P.008)

13

MOTOR

RATED

ARM

AMPS

(P.008)

Rated armature current from motor nameplate

amps * 10

14

MOTOR

RATED

ARM

VOLTS

(P.009)

Rated armature voltage from motor nameplate

volts DC

15

FEEDBACK

SELECT

(P.200)

Type of feedback for speed/voltage loop feedback

0=

ARMATURE

VOLT

; 1=

DC

TACH

; 2=

PULSE

TACH

; 3=

AC

TACH

16

ANALOG

TACH

GAIN

ADJ

(P.201)

Scales analog tachometer feedback signal

gain * 1000

Tunable, configurable, and status data are updated by the regulator approximately every 600 msec.

Table 5.10 – FlexPak 3000 Original Register Map, Drop_2: Master Write Registers, FULL Connection. Configurable Data (Drive Input Data) (Continued)

Register

Bit

Parameter Name (Number)

Description

Settings

Configurable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit =1 and the drive is not running or jogging.