Stop cause word

Bit-packed word indicating why the drive stopped

0

Stop asserted or Run de-asserted (negated)

1

Jog de-asserted for less than 1 second

2

Internal stop request

3

Current limit stop

4

Ramp stop

5

Coast/DB stop

6

Fault stop or self-tuning complete

7

Customer interlock opened

8

Coast/DB interlock opened

9

Main contactor opened

10 – 15

Reserved

23

NOMINAL

AC

LINE

FREQ

(P.306)

Nominal AC line frequency

Hz

24

NOMINAL

AC

LINE

VOLTS

(P.307)

Nominal AC line

RMS

voltage

volts

RMS

25

PLL

MAXIMUM

ERROR

(P.308)

Max. allowed change in line period per AC line cycle

µsec

26

AC

LINE

VOLTAGE

(P.392)

Measured AC line

RMS

voltage

volts

RMS

27

ENHANCED

FLD

VOLT

ADJ

(P.500)

Adjusts the field output voltage

28

FIELD

ECONOMY

DELAY

(P.501)

Time between stopping and entering field economy

minutes

29

FIELD

ECONOMY

ACTIVE

(P.599)

Indicates the present state of field economy

0=

OFF

; 1=

ON

(field economy active)

30

OPEN

SCR

SENSITIVITY

(P.600)

Open

SCR

detection sensitivity adjustment

31

OPEN

SCR

TRIP

THRESH

(P.601)

Open

SCR

detection trip threshold

Table 5.16 – FlexPak 3000 Original Register Map, Drop_4: Master Read Registers, FULL Connection. Tunable, Configurable, and Status Data (Drive Output Data) (Continued)

Register

Bit

Parameter Name (Number)

Description

Settings

Tunable, configurable and status data are updated by the regulator approximately every 600 msec.