3 to15, 17 to 25 – Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual

Page 76

Advertising
background image

7-

8

Aut

o

Max

Net

w

or

k Comm

unicat

ion
O

p

tion
B

oard

14

Alarm latch bits word

Bit-packed word containing latched alarm bits

0

MOTOR

BRUSH

WEAR

LOW

(A00001)

1

AC

LINE

VOLTAGE

LOW

(A00002)

2

AC

LINE

VOLTAGE

HIGH

(A00003)

3 to15

Reserved

15

Last alarm

Alarm code of the most recent alarm

16

CONTROL

SOURCE

SELECT

(P.000)

Selected source for drive control signals

0=

TERMBLK

; 1=

KEYPAD

; 2=

SERIAL

; 3=

NETWORK

17 to 25

Runtime parameters see table 7.2

26

Reserved

27

Stop cause

28

Param Proc Error Number

29

NETW

CONNECT

TYPE

(P.910)

AutoMax network connection type

BASIC

;

FULL

30

AMX

NETW

REF

SELECT

(P.911)

AutoMax network reference selection

DIRECT

;

BROADCAST

N

(

N

=1

TO

8)

31

REGULATOR

SW

VERSION

(P.794)

Regulator board software version

Table 7.5 – WebPak 3000 Register Map, Drop_1: Master Write Registers, BASIC and FULL Connections. Control/Reference Data (Drive Input Data)

Register

Bit

Parameter Name (Number)

Description

Settings

32

Sequencing control word

Word containing drive sequencing and control bits

0

Section run

1

Section off

2

Fault/alarm reset

3

Jog forward

4

Jog reverse

5

Underwind

6

Slack take up

7

Tension on

8

Diameter reset

Control/reference data are read by the regulator every 10 msec.

Table 7.4 – WebPak 3000 Register Map, Drop_1: Master Read Registers, BASIC and FULL Connections. Tunable, Configurable, and Status Data (Drive Output Data) (Continued)

Register

Bit

Parameter Name (Number)

Description

Settings

Tunable, configurable, and status data are updated by the regulator approximately every 600 msec.