F

lex
Pak

3000 Drives

: Alt
e

rnat
e Regist

er
M

a

p

6-

15

18

ANLG

TACH

VOLTS

/1000 (P.203)

Analog tach scaling from tach nameplate (V/1000

RPM

)

volts * 10

19

ARM

VOLTAGE

GAIN

ADJ

(P.204)

Scales the armature voltage signal

gain * 1000

20

ARM

VOLTAGE

ZERO

ADJ

(P.205)

Offset removed from armature voltage feedback

21

Reserved

22

PULSE

TACH

PPR

(P.207)

Pulses per revolution from the pulse encoder nameplate

23

PULSE

TACH

QUADRATURE

(P.208)

Enables or disables pulse encoder quadrature

0=

OFF

; 1=

ON

(quad decode)

24

CURRENT

COMPOUNDING

(P.209)

Sets the level of current compounding

%

25

SPD

LEADLAG

RATIO

(P.213)

Ratio between low and high break frequencies of speed
feedback lead/lag block

26

SPD

LEADLAG

LOW

FREQ

(P.214)

Low break frequency of speed feedback lead/lag block

radians/second * 100

27

SPD

LOOP

LAG

FREQ

(P.215)

Lag break frequency for speed loop forward path lag

radians/second * 100

28

SPD

LEADLAG

SELECT

(P.216)

Speed/voltage loop lead/lag block select

0=

LEAD

/

LAG

; 1=

BYPASS

; 2=

LAG

/

LEAD

29

SPD

LOOP

LAG

BYPASS

(P.217)

Speed/voltage loop lag block bypass

0=

OFF

(not bypassed); 1=

ON

(bypassed)

30

CML

FEEDBACK

GAIN

ADJ

(P.300)

Current minor loop feedback gain adjust

gain * 1000

31

ARMATURE

BRIDGE

POL

(P.394)

Active armature bridge

0=

OFF

(forward); 1=

ON

(reverse)

Table 6.14 – FlexPak 3000 Alternate Register Map, Drop_3: Master Write Registers, FULL Connection. Tunable Data (Drive Input Data)

Register

Bit

Parameter Name (Number)

Description

Settings

33

FIELD

ECONOMY

REF

(P.511)

Reference for field economy mode

% of

MOTOR

HOT

FLD

AMPS

(P.510)

34

FIELD

PI

PROP

GAIN

(P.514)

Proportional gain setting for the field current loop

PI

block gain * 100

35

FIELD

PI

LEAD

FREQ

(P.515)

Lead frequency for the field current loop

PI

block

radians/second * 100

36

FLD

FEEDBACK

GAIN

ADJ

(P.516)

Field current feedback gain adjust

gain * 1000

37

FLD

WEAKEN

THRESHOLD

(P.518)

Where field control loop begins regulating armature
voltage and the field begins to weaken

4095 at

MOTOR

RATED

ARM

VOLTS

(P.009)

38

FLD

WEAKEN

PROP

GAIN

(P.519)

Proportional gain of the field control loop’s armature
voltage regulator

gain * 100

39

FLD

WEAKEN

LEAD

FREQ

(P.520)

PI

block lead break frequency of the field control loop’s

armature voltage regulator

radians/second * 100

Tunable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit = 1.

Table 6.13 – FlexPak 3000 Alternate Register Map, Drop_3: Master Read Registers, FULL Connection. Tunable, Configurable, and Status Data (Drive Output Data) (Continued)

Register

Bit

Parameter Name (Number)

Description

Settings

Tunable, configurable, and status data are updated by the regulator approximately every 600 msec.