Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual

Page 80

Advertising
background image

7-

12

Aut

o

Max

Net

w

or

k Comm

unicat

ion
O

p

tion
B

oard

Table 7.9 – WebPak 3000 Register Map, Drop_2: Master Read Registers, FULL Connection. Tunable, Configurable, and Status Data (Drive Output Data)

Register

Bit

Parameter Name (Number)

Description

Settings

15

AC

LINE

PERIOD

(P.393)

AC line period as measured by the drive in
microseconds

16

ARMATURE

BRIDGE

POL

(P.394)

Indicates which bridge is currently active.

OFF

(forward bridge active;

ON

(reverse

bridge active)

17

ARMATURE

DELTA

(P.399)

Armature firing angle in microseconds

18

CML

FEEDBACK

(P.397)

CML

feedback signal after scaling

19

CML

RAMP

INPUT

TP

(P.390)

Current reference value to the

CML

ramp block

20

CML

SPEED

REFERENCE

(P.391)

Speed reference value to the current minor loop

21

CURRENT

COMPOUND

TP

(P.293)

Trim value that is subracted from the speed reference
based on motor load

22

DIAMETER

ANALOG

(P.821)

Output of the diameter calculator scaled from zero at
empty core to 4095 at full roll diameter

23

DIAMETER

RESET

TP

(P.829)

State of the diameter reset signal

24

DRAW

PERCENTAGE

OUT

(P.196)

Product of the selectrd trim reference value and trim
range value

25

ENCODER

KIT

(P.798)

Indicates if Pulse Encoder kit is installed and passed
diagnostics

INSTALLED

;

NOT

INSTALLED

;

FAILED

DIAGS

26

FIELD

DELTA

(P.588)

Field firing angle indegrees

0 to 180 degree

27

FIELD

ECONOMY

ACTIVE

(P.599)

State of the field economy function

ON

;

OFF

28

FLD

CURRENT

REGULATOR

(P.586)

Indicates if the Field Current Regulator kit is installed
and its rating

NOT

INSTALLED

; 4

AMP

, 10

AMP

, 20

AMP

29

INERTIA

COMPENSATION

(P.244)

Output of the inertia compensation calculator

30

IR

COMPENSATION

TP

(P.290)

Level of

IR

compensation being subtracted from the

measured armature voltage

31

DIAMETER

CALC

OUTPUT

(P.132)

Value of the calculated roll diameter normalized at
1.000 at

EMPTY

CORE

DIAMETER

(P.830)

Tunable, configurable, and status data are updated by the regulator approximately every 600 msec.

Advertising