Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual

Page 88

Advertising
background image

A-2

AutoMax Network Communication Option Board

AUTO

MODE

MIN

BYPASS

(P.111)

2

27

2

48

AUTO

MODE

RAMP

BYPASS

(P.112)

2

28

2

49

AUTO

REFERENCE

SELECT

(P.103)

2

21

3

54

Average

CML

feedback

1

6

BLOWER

MOTOR

STARTER

OPEN

(F00006)

1

10

6

CML

FEEDBACK

GAIN

ADJ

(P.300)

3

30

3

49

CML

PI

LEAD

FREQUENCY

(P.302)

1

26

1

51

CML

PI

PROP

GAIN

(P.301)

1

25

1

50

CML

REF

RATE

LIMIT

(P.303)

1

27

1

52

CML

REFERENCE

(P.396)

3

3

Coast/DB interlock

1

0

10

Coast/DB interlock opened

4

22

8

Coast/DB stop

4

22

5

CONTROL

SOURCE

SELECT

(P.000)

1

15

CONTROLLER

THERMOSTAT

TRIP

(F00009)

1

10

5

CURRENT

COMPOUNDING

(P.209)

1

56

3

24

Current limit stop

4

22

3

Customer interlock

1

0

11

Customer interlock opened

4

22

7

DECELERATION

TIME

(P.002)

1

17

1

41

DIG

OUT

1

CONTACT

TYP

(P.410)

4

50

0

DIG

OUT

1

SELECT

(P.409)

4

48

DIG

OUT

2

CONTACT

TYP

(P.412)

4

50

1

DIG

OUT

2

SELECT

(P.411)

4

49

Drive jogging

1

0

3

Drive ready

1

0

0

Drive running

1

0

1

Drive status word 1

1

0

Table A.1 – Cross Reference of Parameter Name to Drop and

Register (FlexPak 3000 Original Map) (Continued)

Parameter Name (No.)

Drop

Register

Bit

Drive stopping

1

0

5

ENHANCED

FLD

VOLT

ADJ

(P.500)

4

27

4

41

Fault active

1

0

2

Fault latch bits word 1

1

10

Fault log clear and reset

1

32

8

Fault reset

1

32

2

Fault stop or self-tune complete

4

22

6

FEEDBACK

SELECT

(P.200)

1

61

3

15

FIELD

AUTO

WEAKEN

(P.517)

3

57

FIELD

CURRENT

LOSS

(F00004)

1

10

1

FIELD

ECONOMY

ACTIVE

(P.599)

4

29

FIELD

ECONOMY

DELAY

(P.501)

4

28

4

42

FIELD

ECONOMY

REF

(P.511)

3

33

FIELD

FEEDBACK

(P.589)

1

22

3

5

FIELD

LOSS

THRESHOLD

(P.512)

3

56

FIELD

PI

LEAD

FREQ

(P.515)

3

35

FIELD

PI

PROP

GAIN

(P.514)

3

34

FIELD

REF

REGISTER

(P.513)

1

37

FIELD

REFERENCE

(P.590)

3

4

First fault

1

12

FLD

FEEDBACK

GAIN

ADJ

(P.516)

3

36

FLD

WEAKEN

LEAD

FREQ

(P.520)

3

39

FLD

WEAKEN

PROP

GAIN

(P.519)

3

38

FLD

WEAKEN

THRESHOLD

(P.518)

3

37

Forward/reverse command

1

0

4

Forward/reverse select

1

32

4

FREQ

IN

(P.491)

1

20

4

3

FREQ

IN

FULL

SCALE

(P.424)

4

56

FREQ

IN

ZERO

(P.423)

4

55

FREQ

OUT

FULL

SCALE

(P.427)

4

59

FREQ

OUT

SELECT

(P.425)

4

57

FREQ

OUT

ZERO

(P.426)

4

58

I/O Expansion kit digital inputs

4

0

0 – 4

Table A.1 – Cross Reference of Parameter Name to Drop and

Register (FlexPak 3000 Original Map) (Continued)

Parameter Name (No.)

Drop

Register

Bit