Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual

Page 90

Advertising
background image

A-4

AutoMax Network Communication Option Board

OIM

COMMUNICATIONS

TIMEOUT

(F00011)

1

10

13

OPEN

ARMATURE

(F00007)

1

10

7

OPEN

SCR

SENSITIVITY

(P.600)

4

30

4

43

OPEN

SCR

TRIP

THRESH

(P.601)

4

31

4

44

Outer control loop enable

1

32

7

OVERSPEED

(F00003)

1

10

9

Parameter processing error

1

0

12

PLL

MAXIMUM

ERROR

(P.308)

4

25

4

40

POS

CURRENT

LIM

SEL

(P.223)

2

57

POSITIVE

CURRENT

LIM

(P.005)

1

20

1

44

PULSE

TACH

FEEDBACK

(P.292)

3

1

PULSE

TACH

PPR

(P.207)

3

22

3

62

PULSE

TACH

QUADRATURE

(P.208)

3

23

3

63

Ramp stop

4

22

4

REGULATOR

SW

VERSION

(P.794)

1

31

REVERSE

DISABLE

(P.015)

2

17

2

62

Run

1

32

0

S

-

CURVE

ROUNDING

(P.014)

1

46

2

16

SCR

# or

MULTIPLE

SCRS

NOT

OPERATING

(F00030–F00042)

1

10

10

SELF

TUNING

FAULT

(F00060 to

F000099)

1

10

3

Sequencing control word

1

32

SPD

LEADLAG

LOW

FREQ

(P.214)

3

26

3

45

SPD

LEADLAG

RATIO

(P.213)

3

25

3

44

SPD

LEADLAG

SELECT

(P.216)

3

28

3

47

SPD

LOOP

ERROR

(P.297)

3

2

SPD

LOOP

FEEDBACK

(P.296)

1

3

Table A.1 – Cross Reference of Parameter Name to Drop and

Register (FlexPak 3000 Original Map) (Continued)

Parameter Name (No.)

Drop

Register

Bit

SPD

LOOP

LAG

BYPASS

(P.217)

3

29

3

48

SPD

LOOP

LAG

FREQ

(P.215)

3

27

3

46

SPD

LOOP

OUTPUT

(P.299)

1

4

SPD

LOOP

PI

LEAD

FREQ

(P.212)

1

24

1

49

SPD

LOOP

PI

PROP

GAIN

(P.211)

1

23

1

48

SPD

LOOP

REFERENCE

(P.295)

1

2

SPD

SOURCE

SEL

OUT

(P.193)

1

1

Stop

1

32

1

Stop asserted or Run
de-asserted (negated)

22

0

Stop cause word

4

22

STOP

MODE

SELECT

(P.114)

1

54

2

30

STOP

SPEED

THRESHOLD

(P.113)

2

29

2

50

SUSTAINED

OVERLOAD

(F00005)

1

10

2

TACHOMETER

LOSS

(F00002)

1

10

12

Terminal strip auto/manual
input state (terminal 6)

1

0

14

Terminal strip fault/alarm reset
input state (terminal 10)

1

0

15

Terminal strip forward/reverse
input state (terminal 5)

1

0

13

TOP

SPEED

(P.011)

2

13

2

61

TRIM

MODE

SELECT

(P.110)

2

26

2

47

TRIM

OUTPUT

(P.197)

2

31

TRIM

RANGE

(P.109)

1

22

1

47

TRIM

REF

REGISTER

(P.107)

2

24

TRIM

REFERENCE

SELECT

(P.108)

2

25

2

46

Tune/config input enable

1

32

14

Tune/config input enable
loopback

1

0

6

Table A.1 – Cross Reference of Parameter Name to Drop and

Register (FlexPak 3000 Original Map) (Continued)

Parameter Name (No.)

Drop

Register

Bit

Advertising