Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual

Page 57

Advertising
background image

F

lex
Pak

3000 Drives

: Alt
e

rnat
e Regist

er
M

a

p

6-

9

Table 6.5 – FlexPak 3000 Alternate Register Map, Drop_1: Master Write Registers BASIC and FULL Connections. Control/Reference Data (Drive Input Data)

Register

Bit

Parameter Name (Number)

Description

Settings

32

Sequencing control word

Word containing drive sequencing and control bits

0

Run

0 to 1 transition to run

1

Stop

0=stop; 1=not stop

2

Fault reset

0 to 1 transition to reset

3

Jog

0 to 1 transition to jog; 0=stop

4

Fwd/Rev select

0=forward; 1=reverse

5

UNDERWIND

ENABLE

0=

DISABLED

(overwind); 1=

ENABLED

(underwind); (Default=0)

*

6

SPD

LOOP

PI

RESET

0=

OFF

(enable) (default); 1=

ON

(reset)

*

7

Outer control loop enable

0=hold

OCL

in reset; 1=

OCL

enabled

8

Fault log clear and reset

0 to 1 transition to clear

9

Alarm log clear and reset

0 to 1 transition to clear

10

Alarm reset

0 to 1 transition to reset

11

Memory save

0 to 1 transition to save

12&13

Reserved

14

Tune/config input enable. What to read from the network. “Read all”
includes control/reference, tunable, and configurable inputs

0=read only control/reference inputs;
1=read all

15

Tune/config update synchronization flag (master write)

33

Network Reference

Speed/voltage loop or

CML

reference value when

CONTROL

SOURCE

SELECT

(P.000)=

NETWORK

and

AMX

NETW

REF

SELECT

(P.911)=0

4095 at

TOP

SPEED

(P.011)/

MOTOR

RATED

ARM

VOLTS

(P.009) or

MAX

CURRENT

(P.007)

34

Network Input Register 1

Written by network master

Read at

OIM

or

DCM

(

NETW

IN

REG

1, P.905)

35

Network Input Register 2

Written by network master

Read at

OIM

or

DCM

(

NETW

IN

REG

2, P.906)

36

Network Input Register 3

Written by network master

Read at

OIM

or

DCM

(

NETW

IN

REG

3, P.907)

37

FIELD

REF

REGISTER

(P.513)

Reference for the field current loop

4095 at

MOTOR

HOT

FLD

AMPS

(P.510)

38

SPEED

FEEDBACK

GAIN

Controls gain of the speed loop feedback path

Gain * 1000 (1000 to 32000)
(Default=1000 (1.000))

*

*

This parameter is network-only. If the control source is changed from

NETWORK

to something else, this parameter is automatically reset to its default value.

39

SPD

LOOP

PI

INIT

VAL

Initial value of speed loop

PI

block. This value is at the

PI

block

output when block is in reset. Block is in reset when drive is stopped
or bit 6 of sequencing control word (Drop_1, register 32) is set to 1.

4095 at

MAXIMUM

CURRENT

(P.007)

(default=0)

*

Control/reference data are read by the regulator every 5 msec, unless

FEEDBACK

SELECT

(P.200) is set to

ARMATURE

VOLT

, in which case the update time is 10 msec.