Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual

Page 73

Advertising
background image

W
ebPak

3000 Drives

: Regist

er
M

a

p

7-

5

Table 7.3 – WebPak 3000 Register Map, Drop_1: Master Read Registers, BASIC and FULL Connections. Runtime Signal Data (Drive Output Data)

Register

Bit

Parameter Name (Number)

Description

Settings

0

Drive status word 1

Bit-packed word containing information on the present status of the drive

0

Drive ready

1

Drive running

2

Fault active

3

Jogging forward

4

Jogging reverse

5

Underwind active

6

Stopping

7

Tension On active

8

Stall tension active

9

Current mem active

10

Current limit

11

Alarm active

12

Current/speed active

13

Processing error

14

Tune/cnfg enable

15

Network sync

1

Drive status word 2

Bit-packed word containing information on the present status of the drive

0

FN/DB status

1

Customer interlock

2

TB Section Run

3

TB Jog Reverse

4

TB Jog Forward

5

TB Section Off

6

Coast/DB interlock

7

TB Fault reset

8

TB Diameter Sel A

9

TB Diameter Sel B

10

TB Diameter Reset

Runtime signal data are updated by the regulator every 10 msec.