Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual
Page 73

W
ebPak
3000 Drives
: Regist
er
M
a
p
7-
5
Table 7.3 – WebPak 3000 Register Map, Drop_1: Master Read Registers, BASIC and FULL Connections. Runtime Signal Data (Drive Output Data)
Register
Bit
Parameter Name (Number)
Description
Settings
0
Drive status word 1
Bit-packed word containing information on the present status of the drive
0
Drive ready
1
Drive running
2
Fault active
3
Jogging forward
4
Jogging reverse
5
Underwind active
6
Stopping
7
Tension On active
8
Stall tension active
9
Current mem active
10
Current limit
11
Alarm active
12
Current/speed active
13
Processing error
14
Tune/cnfg enable
15
Network sync
1
Drive status word 2
Bit-packed word containing information on the present status of the drive
0
FN/DB status
1
Customer interlock
2
TB Section Run
3
TB Jog Reverse
4
TB Jog Forward
5
TB Section Off
6
Coast/DB interlock
7
TB Fault reset
8
TB Diameter Sel A
9
TB Diameter Sel B
10
TB Diameter Reset
Runtime signal data are updated by the regulator every 10 msec.