Table 5.17 – FlexPak 3000 Drop_4: Master Write Registers, FULL Connection. Tunable Data (Drive Input Data)

Register

Bit

Parameter Name (Number)

Description

Settings

32

ANLG

IN

1

ZERO

ADJ

(P.414)

I/O Expansion kit analog input 1 zero adjust

33

ANLG

IN

1

GAIN

ADJ

(P.415)

I/O Expansion kit analog input 1 gain adjust

gain * 1000

34

ANLG

IN

2

ZERO

ADJ

(P.416)

I/O Expansion kit analog input 2 zero adjust

35

ANLG

IN

2

GAIN

ADJ

(P.417)

I/O Expansion kit

ANALOG

INPUT

2

GAIN

ADJUST

gain * 1000

36

LEVEL

DETECT

1

THRESH

(P.603)

Level detector 1 threshold

% * 10

37

LEVEL

DETECT

1

DELAY

(P.604)

Level detector 1 delay time

seconds * 10

38

LEVEL

DETECT

2

THRESH

(P.606)

Level detector 2 threshold

% * 10

39

LEVEL

DETECT

2

DELAY

(P.607)

Level detector 2 delay time

seconds * 10

40

PLL

MAXIMUM

ERROR

(P.308)

Max. allowed change in line period per AC line cycle

µsec

41

ENHANCED

FLD

VOLT

ADJ

(P.500)

Adjusts the field output voltage

42

FIELD

ECONOMY

DELAY

(P.501)

Time between stopping and entering field economy

minutes

43

OPEN

SCR

SENSITIVITY

(P.600)

Open

SCR

detection sensitivity adjustment

44

OPEN

SCR

TRIP

THRESH

(P.601)

Open

SCR

detection trip threshold

45

ANLG

OUT

1

GAIN

ADJ

(P.420)

I/O Expansion kit analog output 1 gain adjust

gain * 1000

46

ANLG

OUT

2

GAIN

ADJ

(P.422)

I/O Expansion kit analog output 2 gain adjust

gain * 1000

47

Reserved

Tunable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit = 1.