Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual

Page 95

Advertising
background image

Cross Reference of Parameter Name to Drop and Register (FlexPak 3000 Alternate Map)

B-3

IET

(

OVERCURRENT

) (F00001)

1

10

8

In current limit

1

0

9

INERTIA

COMP

SELECT

(P.221)

2

56

Internal stop request

1

26

2

IR

COMPENSATION

(P.206)

2

54

Jog

1

32

3

JOG

ACCEL

/

DECEL

TIME

(P.013)

2

15

2

40

Jog de-asserted > 1 second

1

26

1

JOG

SPEED

1 (P.012)

2

14

2

52

Last alarm

1

14

LEVEL

DETECT

1

DELAY

(P.604)

4

37

LEVEL

DETECT

1

SELECT

(P.602)

4

60

LEVEL DETECT

1

THRESH

(P.603)

4

36

LEVEL

DETECT

2

DELAY

(P.607)

4

39

LEVEL

DETECT

2

SELECT

(P.605)

4

61

LEVEL

DETECT

2

THRESH

(P.606)

4

38

Level detector 1 output

1

0

11

Level detector 2 output

1

0

12

Main contactor opened

1

26

9

MAXIMUM

CURRENT

(P.007)

3

12

3

58

MAXIMUM

SPEED

(P.004)

1

43

2

4

Memory save

1

32

11

MINIMUM

SPEED

(P.003)

1

42

2

3

MOTOR

BRUSH

WEAR

LOW

(A00001)

1

13

0

MOTOR

HOT

FLD

AMPS

(P.510)

3

55

MOTOR

RATED

ARM

AMPS

(P.008)

3

13

3

59

MOTOR

RATED

ARM

VOLTS

(P.009)

3

14

3

60

Motor thermostat

1

1

15

MOTOR

THERMOSTAT

TRIP

(F00008)

1

10

4

NEG

CUR

LIM

INV

EN

(P.226)

3

53

0

NEG

CURRENT

LIM

SEL

(P.224)

2

58

Table B.1 – Cross Reference of Parameter Name to Drop and

Register (FlexPak 3000 Alternate Map) (Continued)

Parameter Name (No.)

Drop

Register

Bit

NEGATIVE

CURRENT

LIM

(P.006)

1

45

2

6

NETW

COMM

LOSS

SEL

(P.901)

3

52

NETW

CONNECT

TYPE

(P.910)

1

28

1

62

NETW

IN

REG

1 (P.905)

1

34

NETW

IN

REG

2 (P.906)

1

35

NETW

IN

REG

3 (P.907)

1

36

NETW

OUT

REG

1

SELECT

(P.902)

1

58

NETW

OUT

REG

2

SELECT

(P.903)

1

59

NETW

OUT

REG

3

SELECT

(P.904)

1

60

NETW

REGISTER

MAP

SEL

(P.914)

1

29

NETW

COMM

TIMEOUT

(F00013)

1

10

14

Network Output Register 1

1

7

Network Output Register 2

1

8

Network Output Register 3

1

9

Network Reference

1

33

NOMINAL

AC

LINE

FREQ

(P.306)

4

23

4

62

NOMINAL

AC

LINE

VOLTS

(P.307)

4

63

4

63

NORMALIZED

INERTIA

(P.222)

1

57

OCL

FEEDBACK

SELECT

(P.804)

2

60

OCL

LEADLAG

LOW

FREQ

(P.806)

2

38

OCL

LEADLAG

RATIO

(P.807)

2

39

OCL

LEADLAG

SELECT

(P.805)

2

37

OCL

OUTPUT

(P.848)

1

21

OCL

PI

LEAD

FREQ

(P.809)

1

53

OCL

PI

NEGATIVE

LIMIT

(P.811)

1

55

OCL

PI

POSITIVE

LIMIT

(P.810)

1

54

OCL

PI

PROP

GAIN

(P.808)

1

52

OCL

PROP

TRIM

SELECT

(P.813)

3

53

1

OCL

RAMP

OUTPUT

(P.846)

2

11

OCL

REF

RAMP

TIME

(P.802)

2

35

OCL

REF

REGISTER

(P.801)

2

34

OCL

REF

ROUNDING

(P.803)

2

36

OCL

REFERENCE

SELECT

(P.800)

2

59

OCL

TRIM

RANGE

(P.812)

2

55

Table B.1 – Cross Reference of Parameter Name to Drop and

Register (FlexPak 3000 Alternate Map) (Continued)

Parameter Name (No.)

Drop

Register

Bit

Advertising